Safety Tips to Gas Users :
Prevent Gas Accidents - Case Analysis

• Gas Lighter Accident• Flashover Involving Cassette Cooker
• Gas Leak from Cooker • Gas Leak from Flexible Gas Tubing
• Non-approved Gas Water Heater Incident

Gas Lighter Accident
(I090327001)
Incident A man placed an LPG lighter on the panel of a double burner gas cooking stove in the kitchen. He then started cooking on the stove. When he left the kitchen to take a phone call, the lighter had a minor explosion. Luckily, the man was not hurt by the explosion.
Cause The plastic shell of the lighter cracks under the heat of the stove. LPG leaking out and is ignited by the flame of the stove, causing the minor explosion.
Prevention Tips Keep lighters away from flame or any environment with a temperature higher than 50°C, such as near an electrical appliance that gives off heat or a cooking stove. Lighters should be stored in a dry, cool, well-ventilated place which is inaccessible to children. Never leave lighters in a car.
Photo
The lighter involved in the incident
Back to Contents
Flashover Involving Cassette Cooker
(I110330003)
Incident The male householder got a cassette cooker out to prepare hot pot at home. He inserted the LPG cartridge and tried to switch on the cassette cooker. There was a flashover. The female householder rushed to get the burning cassette cooker to the bathroom to put out the fire. Her left arm suffered minor burns in the incident.
Cause Investigation found that the cassette cooker involved in the incident was purchased more than 10 years ago. It has no flame failure device and has not been properly maintained. The ageing rubber seal ring at the connection between cartridge nozzle and cooker is the cause of the gas leak. A flashover occurred when the male householder tried to switch on the gas-leaking cassette cooker.
Prevention Tips Purchase cassette cooker bearing the GU mark and follow the instructions on the LPG cartridge in handling and changing cartridges. Do not use non-approved accessories.
Photo
Position of gas leak
Back to Contents
Gas Leak from Cooker
(I090302001)
Incident A strange odour from a flat was detected and reported to the police by a neighbour. Firemen broke into the flat and found that the left burner of a double burner LPG cooking stove had not been switched off completely, resulting in the LPG leak. Luckily, the leak was detected in time, before any serious incident, such as fire or explosion, happened.
Cause The LPG cooking stove involved in the incident is a non-approved gas appliance (without the GU mark). Although fitted with a flame failure device, that device could not function normally. As the burner on the left is neither switched off completely nor ignited, it results in the LPG leak.
Prevention Tips Purchase gas appliances that bear the GU mark. Arrange for a registered gas contractor to conduct safety checks on the appliance once every 18 months to ensure best performance of the appliance. Check if the switch of the gas appliance is turned off properly after cooking or cleaning.
Photo
The non-approved gas appliance involved in the incident
Back to Contents
Gas Leak from Flexible Gas Tubing
(I090209001)
Incident It is a gas leak incident involving an LPG cylinder left on the ground outside a village house. Firemen arriving at the scene switched off and removed the regulator of the LPG cylinder to stop the gas leak.
Cause The flexible tubing and regulator of the LPG cylinder have already reached the end of their service life, and there are a number of surface cracks on the flexible tubing. This is the cause of the incident.
Prevention Tips Use flexible gas tubing that is approved by EMSD. Arrange for a registered gas contractor to conduct safety checks on gas installations every 18 months. Change the regulator and flexible tubing before the expiry of service life according to the instructions of the registered gas contractor.
Photo
A number of cracks are found on the flexible gas tubing
Back to Contents
Non-approved Gas Water Heater Incident
(I091230003)
Incident A member of the public was killed by inhaling excessive amounts of carbon monoxide while using a non-EMSD approved water heater in a shower.
Cause The flueless gas water heater used by the deceased is not approved by EMSD. The bathroom was filled with carbon monoxide discharged by the water heater, and the ventilation fan was not turned on when the deceased was taking the shower. That is how the incident happens.
Prevention Tips Do not purchase or use gas water heaters that are not approved by EMSD.