Recognized Certification Bodies for Electrical Products

Currently, there are 148 certification bodies, covering 28 countries/regions recognized by the Director of Electrical and Mechanical Services as Recognized Certification Bodies:

China > China S to Z

Name & AddressSpecified Classes of
Electrical Products to be Certified

SGS-CSTC Standards Technical Services Co. Ltd. Anhui Branch

1&2/F, West of Building C12, Gongtou Liheng Industrial Square, Fanhua Road, Economic & Technological Development Area, Hefei, Anhui, China

Tel: (86)021-61915638

As detailed in the Laboratory Accreditation Certificate No.: CNAS L9875 dated 17 July 2019 and the attached appendices for the scope of accreditation and excluding items issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 17 July 2019.

Classes of Electrical Products ... Standards Applicable

SGS-CSTC Standard Technical Services Co., Ltd. Guangzhou Branch

No.198, Kezhu Road, Science City, Economic & Technological Development Area, Guangzhou, Guangdong, China

Tel: +86 20 8215 5379
Fax: +86 20 8207 5058
Email: Bonnie.Liao@sgs.co

As detailed in the Laboratory Accreditation Certificate No. ATL 0032 dated 02.08.2019 and the attached appendices for the scope of accreditation issued by GCC Accreditation Center (GAC) dated 06.10.2021.

Classes of Electrical Products ... Standards Applicable

SGS-CSTC Standards Technical Services Co. Ltd. Ningbo Branch

No. 1177, Lingyun Road, Hi-Tech Zone, Ningbo, Zhejiang, China

Tel: (86)574-87767006

As detailed in the Laboratory Accreditation Certificate No. CNAS L4305 dated 17.10.2018 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 13.11.2019.

Classes of Electrical Products ... Standards Applicable

SGS-CSTC Standards Technical Services Co., Ltd. Shunde Branch

Building 1, European Industrial Park, No.1, Shunhe South Road, Wusha, Daliang, Shunde District, Foshan, Guangdong, China

Tel: + 86 (0)757 2280 5731
Fax: + 86 (0)757 2280 5891
Email: Lexie.Yang@sgs.com

As detailed in the Laboratory Accreditation Certificate No. Accreditation Certificate No. ATL 0080 dated 4.8.2019 and the attached appendices for the scope of accreditation issued by the GCC Accreditation Center (GAC) dated 5.4.2022.

Classes of Electrical Products ... Standards Applicable

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. Testing Center

No. 588 West Jindu Rd, Xinqiao Town, Songjiang District, Shanghai

Tel: 020 32136901
Fax: 020 82075058

As detailed in the Laboratory Accreditation Certificate No. CNAS L0599 dated 10.18.2018 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 10.18.2018.

  • Lampholders
    • Edison screw type lampholders
  • Household and Similar Equipment
    • Air-cleaning appliances
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Air fresheners
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Appliances for heating liquids
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Appliances for skin or hair care
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Battery chargers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Cleaning appliances
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Clothes dryers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Cooking ranges
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Deep fat fryers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Dishwashers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Electric dry irons
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Electric fans
      (Except for 20.101 hardness test of fan blades, 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Electric hair dryers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Electric ironers (with padded surface for pressing)
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Electric kitchen machines
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Electric pumps for liquids
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Electric sauna heating appliances
      (Only Prefabricated sauna. Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Electric shavers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Electric steam irons
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Electric toilets
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Electrical appliances for use with aquariums and garden ponds (e.g. aerators, aquarium heaters)
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Fabric steamers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Floor treatment machines
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Food freezers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Frying pans
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Grills
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Hair clippers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Humidifiers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Ice-makers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Induction hotplates
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Insect killers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Insect repellers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Massage appliances
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Microwave ovens
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Oral hygiene appliances
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Outdoor barbecues
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Ovens
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Power transformers and power supply units
      (Only accredited for Single-phase. Except for 19.9 Oxygen bomb test and 19.10 scratch test.)
    • Range hoods
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Refrigerators
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Roasters
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Room heaters
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Sewing machines
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Spin extractors
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Toasters
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Towel rails
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.
    • Tumble dryers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Vacuum cleaners
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation,3.101,watersuction cleaning appliance,21.101 , 21.102, 21.103,21.104,21.105 test on current carrying hose.)
    • Vaporizers
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Warming plates
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.
    • Washing machines
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
    • Water suction cleaning appliances
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation,3.101,watersuction cleaning appliance,21.101 , 21.102, 21.103,21.104,21.105 test on current carrying hose)
    • Wet scrubbing machines
      (Except for 22.32 Oxygen bomb test;22.48 tests for hose, 24.1.1 capacitor test, 24.1.4 automatic control, annex F Capacitors, annex J Coated printed circuit boards, annex R Software evaluation.)
  • Lighting
    • A.C. supplied electronic ballasts of tubular fluorescent lamps
    • Ballasts for discharge lamps
    • Ballasts for tubular fluorescent lamps
    • Double capped fluorescent lamps (only for length of lamp≤1200mm)
    • Electronic step-down convertors for filament lamps
    • Floodlights
    • Handlamps
    • Incandescent lamps
      (Except for safety at end of life. Accredited only for GU10, GZ10 and edison screw cap or bases)
    • Lighting chains
    • Luminaires for aquarium
    • Luminaires, fixed, general purpose
    • Luminaires for emergency
    • Luminaires with built-in transformers for filament lamps
    • Nightlights
    • Portable general purpose luminaires
    • Portable luminaires for garden use
    • Recessed luminaires
    • Self-ballasted lamps
    • Single-capped fluorescent lamps
    • Tungsten filament lamps
    • Tungsten halogen lamps
      (Except for safety at end of life.)
  • Information Technology Equipment
    • Copying machine
      (Except for 1.5.6 Capacitor, 1.5.7 Resistor, 2.10.3.2 transient voltages, 2.10.5.4 Discharge of semiconductor,2.10.8Test on coated printed boards and coated components, 3.2.5.1 AC power supply cord, 4.2.8 Cathode ray tubes,4.2.9 High pressure lamps, 4.3.12 Flammable liquids, 4.3.13.2-5 Radiation, annex A.3 Hot flaming oil test, annex G Alternative method for determining minimum clearance, annex K Thermal controls, annex U Insulated winding wires for use without interleaved insulation, annex AA Mandrel test, annex CC Evaluation of integrated circuit (IC) current limiters, annex Zx Sound pressure test.)
    • Data processing equipment
      (Except for 1.5.6 Capacitor, 1.5.7 Resistor, 2.10.3.2 transient voltages, 2.10.5.4 Discharge of semiconductor,2.10.8Test on coated printed boards and coated components, 3.2.5.1 AC power supply cord, 4.2.8 Cathode ray tubes,4.2.9 High pressure lamps, 4.3.12 Flammable liquids, 4.3.13.2-5 Radiation, annex A.3 Hot flaming oil test, annex G Alternative method for determining minimum clearance, annex K Thermal controls, annex U Insulated winding wires for use without interleaved insulation, annex AA Mandrel test, annex CC Evaluation of integrated circuit (IC) current limiters, annex Zx Sound pressure test.)
    • Facsimile machine
      (Except for 1.5.6 Capacitor, 1.5.7 Resistor, 2.10.3.2 transient voltages, 2.10.5.4 Discharge of semiconductor,2.10.8Test on coated printed boards and coated components, 3.2.5.1 AC power supply cord, 4.2.8 Cathode ray tubes,4.2.9 High pressure lamps, 4.3.12 Flammable liquids, 4.3.13.2-5 Radiation, annex A.3 Hot flaming oil test, annex G Alternative method for determining minimum clearance, annex K Thermal controls, annex U Insulated winding wires for use without interleaved insulation, annex AA Mandrel test, annex CC Evaluation of integrated circuit (IC) current limiters, annex Zx Sound pressure test.)
    • Modem
      (Except for 1.5.6 Capacitor, 1.5.7 Resistor, 2.10.3.2 transient voltages, 2.10.5.4 Discharge of semiconductor,2.10.8Test on coated printed boards and coated components, 3.2.5.1 AC power supply cord, 4.2.8 Cathode ray tubes,4.2.9 High pressure lamps, 4.3.12 Flammable liquids, 4.3.13.2-5 Radiation, annex A.3 Hot flaming oil test, annex G Alternative method for determining minimum clearance, annex K Thermal controls, annex U Insulated winding wires for use without interleaved insulation, annex AA Mandrel test, annex CC Evaluation of integrated circuit (IC) current limiters, annex Zx Sound pressure test.)
    • Telephone answering machines
      (Except for 1.5.6 Capacitor, 1.5.7 Resistor, 2.10.3.2 transient voltages, 2.10.5.4 Discharge of semiconductor,2.10.8Test on coated printed boards and coated components, 3.2.5.1 AC power supply cord, 4.2.8 Cathode ray tubes,4.2.9 High pressure lamps, 4.3.12 Flammable liquids, 4.3.13.2-5 Radiation, annex A.3 Hot flaming oil test, annex G Alternative method for determining minimum clearance, annex K Thermal controls, annex U Insulated winding wires for use without interleaved insulation, annex AA Mandrel test, annex CC Evaluation of integrated circuit (IC) current limiters, annex Zx Sound pressure test.)
    • Typewriters
      (Except for 1.5.6 Capacitor, 1.5.7 Resistor, 2.10.3.2 transient voltages, 2.10.5.4 Discharge of semiconductor,2.10.8Test on coated printed boards and coated components, 3.2.5.1 AC power supply cord, 4.2.8 Cathode ray tubes,4.2.9 High pressure lamps, 4.3.12 Flammable liquids, 4.3.13.2-5 Radiation, annex A.3 Hot flaming oil test, annex G Alternative method for determining minimum clearance, annex K Thermal controls, annex U Insulated winding wires for use without interleaved insulation, annex AA Mandrel test, annex CC Evaluation of integrated circuit (IC) current limiters, annex Zx Sound pressure test.)
    • Visual Display Units for computer
      (Except for 1.5.6 Capacitor, 1.5.7 Resistor, 2.10.3.2 transient voltages, 2.10.5.4 Discharge of semiconductor,2.10.8Test on coated printed boards and coated components, 3.2.5.1 AC power supply cord, 4.2.8 Cathode ray tubes,4.2.9 High pressure lamps, 4.3.12 Flammable liquids, 4.3.13.2-5 Radiation, annex A.3 Hot flaming oil test, annex G Alternative method for determining minimum clearance, annex K Thermal controls, annex U Insulated winding wires for use without interleaved insulation, annex AA Mandrel test, annex CC Evaluation of integrated circuit (IC) current limiters, annex Zx Sound pressure test.)
  • Portable Tools ( which are designed for household use )
    • Drills
      (Except for: Three phase tools; 14.6 Residual current devices; Components (Switch, temperature controller, etc, which are tested with appliance); Screw torque which screw's diameter is larger than 5.6mm and Radiation, toxicity and similar hazards; Annex I Measurement of noise and vibration emissions)
    • Screwdrivers
      (Except for: Three phase tools; 14.6 Residual current devices; Components (Switch, temperature controller, etc, which are tested with appliance); Screw torque which screw's diameter is larger than 5.6mm and Radiation, toxicity and similar hazards; Annex I Measurement of noise and vibration emissions)
    • Sanders
      (Except for: Three phase tools; 14.6 Residual current devices; Components (Switch, temperature controller, etc, which are tested with appliance); Screw torque which screw's diameter is larger than 5.6mm and Radiation, toxicity and similar hazards; Annex I Measurement of noise and vibration emissions)
  • Electronics, Entertainment
    • Amplifiers
      (Except for 7.2 Heat resistance of insulating material, 8.17 Requirements for insulated winding wires for use without additional interleaved insulation, 8.18 Endurance test for wound components with insulated winding wires without additional interleaved insulation, 8.22 Non-separable thin sheet material, 12.1.2 Bump test, annex J Coated printed circuit boards Alternative method for determining minimum clearances, 14.1 Resistor, 14.2 Capacitor, 14.6 Switch, 14.11 Opt couplers, annex H Insulated winding wires for use without interleaved insulation.)
    • Audio equipment
      (Except for 7.2 Heat resistance of insulating material, 8.17 Requirements for insulated winding wires for use without additional interleaved insulation, 8.18 Endurance test for wound components with insulated winding wires without additional interleaved insulation, 8.22 Non-separable thin sheet material, 12.1.2 Bump test, annex J Coated printed circuit boards Alternative method for determining minimum clearances, 14.1 Resistor, 14.2 Capacitor, 14.6 Switch, 14.11 Optocouplers, annex H Insulated winding wires for use without interleaved insulation.)
    • Karaoke equipment
      (Except for 7.2 Heat resistance of insulating material, 8.17 Requirements for insulated winding wires for use without additional interleaved insulation, 8.18 Endurance test for wound components with insulated winding wires without additional interleaved insulation, 8.22 Non-separable thin sheet material, 12.1.2 Bump test, annex J Coated printed circuit boards Alternative method for determining minimum clearances, 14.1 Resistor, 14.2 Capacitor, 14.6 Switch, 14.11 Optocouplers, annex H Insulated winding wires for use without interleaved insulation.)
    • Television
      (Except for 7.2 Heat resistance of insulating material, 8.17 Requirements for insulated winding wires for use without additional interleaved insulation, 8.18 Endurance test for wound components with insulated winding wires without additional interleaved insulation, 8.22 Non-separable thin sheet material, 12.1.2 Bump test, annex J Coated printed circuit boards Alternative method for determining minimum clearances, 14.1 Resistor, 14.2 Capacitor, 14.6 Switch, 14.11 Optocouplers, annex H Insulated winding wires for use without interleaved insulation.)
    • Video equipment
      (Except for 7.2 Heat resistance of insulating material, 8.17 Requirements for insulated winding wires for use without additional interleaved insulation, 8.18 Endurance test for wound components with insulated winding wires without additional interleaved insulation, 8.22 Non-separable thin sheet material, 12.1.2 Bump test, annex J Coated printed circuit boards Alternative method for determining minimum clearances, 14.1 Resistor, 14.2 Capacitor, 14.6 Switch, 14.11 Optocouplers, annex H Insulated winding wires for use without interleaved insulation.)

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Testing Center

No.4 Jianghao Industrial Factory Area, No. 430, Jihua Road, Bantian Street, Longgang District, Shenzhen, Guangdong, China

Tel: 020-32136901
Fax: 020-82075058

As detailed in the Laboratory Accreditation Certificate No. CNAS L2929 dated 22.9.2017 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 19.12.2018.

  • Adaptors
    • 13A adaptor
  • Extension Units
    • For plug portion (3-pin 13A)
    • For socket portion
    • For cable reels
  • Cables and Cords
    • Cord sets
  • Switches for Appliances and Automatic Controls for Electrical Household Appliances
    • Switches for appliances
      (IEC 61058-1 Except for: cord operated switch)
    • Cord operated switch
      (IEC 61058-2-1Accredited only for: clauses 12 and 18. other parameters same as 7-21)
  • Household and Similar Equipment
    • Battery chargers
      (Accredited only for Clause 8.1 and 21.1, 21.101, 21.102, others same as 2-1)
    • Power transformers and power supply units
      1.Determination of Working voltage, 6.Output voltage and output current under load, 8.Short-circuit voltage, 9.Heating, 10.Short circuit and overload protection, 23.Overload Protection Device Test, 33.Electronic Circuits fault Test
      (Accredited only for: single phase voltage up to 300V, 50/60Hz, 75kVA, and test load not more than 150V and 500A.)
      14.Ingress of Dust and Water Test
      (Accredited only for: IPX1~IPX4 sample size (mm):≤1000×1000×1000; IPX5 and IPX6 sample size(mm):≤3000×1200×1800; IPX7 sample size(mm): Diameter or Length or Width≤500mm,Height≤1000mm; IPX8 sample size(mm): Diameter or Length or Width≤350mm,Height≤1000mm; IP5X to IP6X sample size (mm): ≤1200×700 ×800)
      15. Humidity Treatment Test
      (Accredited only: Sample size (mm): ≤1000×1000×1000)
      20. Protective earth conductor current test
      (Accredited only for: Test current not more than 60A)
    • Safety isolating transformers and power supply units incorporating safety isolating transformers
      (Same as 3-1)
    • Transformers and power supplies for toys
      1. Determination of Working voltage, 2. Marking Durability Test, 3. Touch current and voltage test, 6. Accessibility to hazardous live parts, 7. Protection against hazardous electrical discharge, 8. Output voltage and output current under load, 9. No-load output voltage, 10. Short-circuit voltage, 11. Heating, 12. Short circuit and overload protection, 13. Impact Test, 14.Drop Test, 15. Tumbling Barrel Test and Torque Test, 20. Insulation Resistance Test, 21. Dielectric Strength Test, 22. Double voltage double frequency, 23. Touch current test, 24. Protective earth conductor current test, 25. Insulating coating test, 26. Plug portion test for direct plug-in equipment, 27. Overload Protection Device Test, 28. Flexing Test (For cords are moved while in normal operation), 29. Cord Anchorage Test, 30. Protective earthing resistance test, 31. Screw Torque Test, 32. Creepage distance, clearance and distance through insulation, 33. Mandrel Test, 34. Ball Pressure Test, 35. Glow Wire Test, 36. Resistance to tracking, 37. Electronic Circuits fault Test, 38. Impact Test
      (Accredited only for: single phase with rated supply voltage up to 250V, 50/60Hz, output <40A)
      16. Ingress of Dust and Water Test
      (Accredited only for IP68, IPX1 to IPX4:1000mm(L)x1000mm(W)x1000mm(H); IPX5 and IPX6:3000mm(L)x1200mm(W)x1800mm(H); IPX7: Diameter or Length Width:500mm, Height:1000mm; IPX8: Diameter or Length Width:350mm, Height:1000mm; IP5X to IP6X: Max.1200(L)x700(W)x800(H)mm)
      17. Humidity Treatment Test
      (Accredited only for sample with size less than 1mx1mx1m)
    • Switch mode power supply units and transformers for switch mode power supply units
      (Accredited only for Clause 18.101, others same as 3-1)
  • Installation Accessories and Connection Devices
    • Appliance couplers
    • Connecting devices
    • Socket-outlets
    • Switches
      (Accredited only for: clauses 10, 13, 18, 101 and 102. other parameters same as 7-25)
  • Information Technology Equipment
    14. Humidity conditioning,
    (Accredited only for sample with size less than 1mx1mx1m)
    • Copying machine
    • Data processing equipment
    • Facsimile machine
    • Modem
    • Telephone answering machines
    • Typewriters
    • Visual Display Units for computer
  • Electronics, Entertainment
    16. Humidity conditioning,
    (Accredited only for sample with size less than 1mx1mx1m)
    20. Vibration test
    (Accredited only for product with contact area less than 500mmx500mm and weight less than 300kg)
    41. Additional requirements for apparatus with protection against splashing water
    (Accredited only for IPX1 to IPX4:1000mm(L)x1000mm(W)x1000mm(H); IPX5 and IPX6: 3000mm(L)x1200mm(W)x1800mm(H); IPX7: Diameter or Length Width:500mm, Height: 1000mm; IPX8: Diameter or Length Width:350mm, Height:1000mm)
    • Amplifiers
    • Audio equipment
    • Karaoke equipment
    • Television
    • Video equipment

Shenzhen Academy of Metrology and Quality Inspection

Metrology and Quality
Inspection Building
Longzhu Avenue
Middle Nanshan District
Shenzhen China

Tel :86 755 6941696
Fax: 86 755 6941615

As detailed in the Certificate of Laboratory Accreditation No. 0157 dated November 30, 1998 issued by the China National Accreditation Committee for Laboratories, and the Notification Letter No. (1998) 157 dated November 30, 1998 issued by China State Bureau of Quality and Technical Supervision. (Standards will be based on IEC Series)

  • Fans;
  • range hoods;
  • toasters, grills, roasters and similar appliances;
  • kitchen machines;
  • electric irons;
  • instantaneous water heaters;
  • storage water heaters;
  • appliances for skin and hair care;
  • appliances for heating liquids;
  • room heaters;
  • massage appliances;
  • luminaries:
    • portable general purpose luminaries;
    • fixed general purpose luminaries;
  • plugs and socket-outlets for household and similar purposes;
  • rubber insulated cables of rated voltages up to and including 450/750V;
  • polyvinyl chloride insulated cables of rated voltages up to and including 450/750V.

Shenzhen Accurate Technology Co., Ltd.

1/F., Building A, Changyuan New Material Port, Science & Industry Park, Nanshan District, Shenzhen, Guangdong, China

Tel: 0755-26503293
Fax: 0755-26503396

As detailed in the Laboratory Accreditation Certificate No. CNAS L3193 dated 20.9.2007 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 28.7.2010.

  • Household appliances :-
    • Fans
    • Room heaters
    • Vacuum cleaners and water-suction cleaning appliances
    • Appliances for skin or hair care
    • Electric irons
    • Grills, toasters and similar portable cooking appliances
    • Kitchen machines
    • Appliances for heating liquids
    • Shavers, hair clippers and similar appliances
    • Battery chargers
    • Massage appliances
    • Projectors and similar appliances
    • Insect killers
    • Outdoor barbecues
    • Drives for vertically moving garage doors for residential use
    • Humidifiers
    • Warming plates
    • Refrigerating appliances, ice-cream appliances and ice makers
    • Pumps
    • Clothes dryers and towel rails
    • Portable heating tools and similar appliances
    • Drives for rolling shutters, awnings, blinds and similar equipment
    • Measuring Methods for Determining the Magnetic Flux Density
  • Luminaires :-
    • Fixed general purpose luminaires
    • Recessed luminaires
    • Luminaires for road and street lighting
    • Portable general purpose luminaires
    • Floodlights
    • Portable luminaires for garden use
    • Photo and film luminaires (non-professional)
    • Aquarium luminaires
    • Mains socket-outlet mounted nightlights
    • Luminaires for stage lighting, television file and photographic studios (outdoor and indoor)
    • Lighting chains
    • Self-ballasted lamps for general lighting services
    • Lamp controlgear
    • d.c. or a.c. supplied electronic step-down converters for filament lamps
    • a.c. supplied electronic ballasts for fluorescent lamps
    • d.c. or a.c. supplied electronic ballasts for discharge lamps (excluding fluorescent lamps)
    • d.c. or a.c. supplied electronic controlgear for LED modules
    • LED modules for general lighting
  • Power transformers, power supply units and similar appliances :-
    • Safety isolating transformers for general use
    • Transformers for switch mode power supplies
  • Electrical equipment for measurement, control, and laboratory use

  • Uninterruptible power systems

  • Audio, video and similar electronic apparatus

  • Information technology equipment

Shenzhen Alpha Product Testing Co., Ltd.

Building i, No.2, Lixin Road, Fuyong Street, Bao’an District, Shenzhen, Guangdong, China

Tel: 86-755-29766001
Fax: 86-755-26736857

As detailed in the Laboratory Accreditation Certificate No. CNAS L7472 dated 25.12.2017 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 25.12.2007.

  • Information technology equipment
    • Copying machine
      (Except for: Three-phase product and single-phase product with rating >3KA; 2.3 Test for operating voltage generated externally; 2.8.7.3 endurance test; 2.10.5.4 Semiconductor devices; 2.10.5.12 Wire in wound components; 2.10.6.2 Coated printed boards; 2.10.8.4 Abarasion resistance test; annex G Alternative method for determining minimumclearances; annex U Insulated winding wires for use without interleaved insulation; 4.2.8 Cathode ray tube; 4.3.12 Flammable liquids; 4.3.13 annex H Radiation; 6.2 Impulse test)

    • Data processing equipment
      (Except for: Three-phase product and single-phase product with rating >3KA; 2.3 Test for operating voltage generated externally; 2.8.7.3 endurance test; 2.10.5.4 Semiconductor devices; 2.10.5.12 Wire in wound components; 2.10.6.2 Coated printed boards; 2.10.8.4 Abarasion resistance test; annex G Alternative method for determining minimumclearances; annex U Insulated winding wires for use without interleaved insulation; 4.2.8 Cathode ray tube; 4.3.12 Flammable liquids; 4.3.13 annex H Radiation; 6.2 Impulse test)

    • Facsimile machine
      (Except for: Three-phase product and single-phase product with rating >3KA; 2.3 Test for operating voltage generated externally; 2.8.7.3 endurance test; 2.10.5.4 Semiconductor devices; 2.10.5.12 Wire in wound components; 2.10.6.2 Coated printed boards; 2.10.8.4 Abarasion resistance test; annex G Alternative method for determining minimumclearances; annex U Insulated winding wires for use without interleaved insulation; 4.2.8 Cathode ray tube; 4.3.12 Flammable liquids; 4.3.13 annex H Radiation; 6.2 Impulse test)

    • Modem
      (Except for: Three-phase product and single-phase product with rating >3KA; 2.3 Test for operating voltage generated externally; 2.8.7.3 endurance test; 2.10.5.4 Semiconductor devices; 2.10.5.12 Wire in wound components; 2.10.6.2 Coated printed boards; 2.10.8.4 Abarasion resistance test; annex G Alternative method for determining minimumclearances; annex U Insulated winding wires for use without interleaved insulation; 4.2.8 Cathode ray tube; 4.3.12 Flammable liquids; 4.3.13 annex H Radiation; 6.2 Impulse test)

    • Telephone answering machines
      (Except for: Three-phase product and single-phase product with rating >3KA; 2.3 Test for operating voltage generated externally; 2.8.7.3 endurance test; 2.10.5.4 Semiconductor devices; 2.10.5.12 Wire in wound components; 2.10.6.2 Coated printed boards; 2.10.8.4 Abarasion resistance test; annex G Alternative method for determining minimumclearances; annex U Insulated winding wires for use without interleaved insulation; 4.2.8 Cathode ray tube; 4.3.12 Flammable liquids; 4.3.13 annex H Radiation; 6.2 Impulse test)

    • Typewriters
      (Except for: Three-phase product and single-phase product with rating >3KA; 2.3 Test for operating voltage generated externally; 2.8.7.3 endurance test; 2.10.5.4 Semiconductor devices; 2.10.5.12 Wire in wound components; 2.10.6.2 Coated printed boards; 2.10.8.4 Abarasion resistance test; annex G Alternative method for determining minimumclearances; annex U Insulated winding wires for use without interleaved insulation; 4.2.8 Cathode ray tube; 4.3.12 Flammable liquids; 4.3.13 annex H Radiation; 6.2 Impulse test)

    • Visual Display Units for computer
      (Except for: Three-phase product and single-phase product with rating >3KA; 2.3 Test for operating voltage generated externally; 2.8.7.3 endurance test; 2.10.5.4 Semiconductor devices; 2.10.5.12 Wire in wound components; 2.10.6.2 Coated printed boards; 2.10.8.4 Abarasion resistance test; annex G Alternative method for determining minimumclearances; annex U Insulated winding wires for use without interleaved insulation; 4.2.8 Cathode ray tube; 4.3.12 Flammable liquids; 4.3.13 annex H Radiation; 6.2 Impulse test)

  • Electronics, Entertainment
    • Amplifiers
      (Except for: Three-phase product and single-phase product with rating >3KA; 8.17 Requirements for insulated winding wires for use without additional interleaved insulation; 8.18 Endurance test for wound components with insulated winding wires without additional interleaved insulation; 8.22 Test specifications of non-separable thin sheet material; annex H winding wires for use without interleaved insulation; annex J Alternative method for determining minimum clearances; 14.2 Capacitors; 14.4 High voltage assemblies; 14.5 Protective devices; 14.6 Switches; 14.7 Safety interlocks; 14.11 Optocouplers; 14.12 Surge suppression varistors; 16.1 flexible cords)

    • Audio equipment
      (Except for: Three-phase product and single-phase product with rating >3KA; 8.17 Requirements for insulated winding wires for use without additional interleaved insulation; 8.18 Endurance test for wound components with insulated winding wires without additional interleaved insulation; 8.22 Test specifications of non-separable thin sheet material; annex H winding wires for use without interleaved insulation; annex J Alternative method for determining minimum clearances; 14.2 Capacitors; 14.4 High voltage assemblies; 14.5 Protective devices; 14.6 Switches; 14.7 Safety interlocks; 14.11 Optocouplers; 14.12 Surge suppression varistors; 16.1 flexible cords)

    • Karaoke equipment
      (Except for: Three-phase product and single-phase product with rating >3KA; 8.17 Requirements for insulated winding wires for use without additional interleaved insulation; 8.18 Endurance test for wound components with insulated winding wires without additional interleaved insulation; 8.22 Test specifications of non-separable thin sheet material; annex H winding wires for use without interleaved insulation; annex J Alternative method for determining minimum clearances; 14.2 Capacitors; 14.4 High voltage assemblies; 14.5 Protective devices; 14.6 Switches; 14.7 Safety interlocks; 14.11 Optocouplers; 14.12 Surge suppression varistors; 16.1 flexible cords)

    • Television
      (Except for: Three-phase product and single-phase product with rating >3KA; 8.17 Requirements for insulated winding wires for use without additional interleaved insulation; 8.18 Endurance test for wound components with insulated winding wires without additional interleaved insulation; 8.22 Test specifications of non-separable thin sheet material; annex H winding wires for use without interleaved insulation; annex J Alternative method for determining minimum clearances; 14.2 Capacitors; 14.4 High voltage assemblies; 14.5 Protective devices; 14.6 Switches; 14.7 Safety interlocks; 14.11 Optocouplers; 14.12 Surge suppression varistors; 16.1 flexible cords)

    • Video equipment
      (Except for: Three-phase product and single-phase product with rating >3KA; 8.17 Requirements for insulated winding wires for use without additional interleaved insulation; 8.18 Endurance test for wound components with insulated winding wires without additional interleaved insulation; 8.22 Test specifications of non-separable thin sheet material; annex H winding wires for use without interleaved insulation; annex J Alternative method for determining minimum clearances; 14.2 Capacitors; 14.4 High voltage assemblies; 14.5 Protective devices; 14.6 Switches; 14.7 Safety interlocks; 14.11 Optocouplers; 14.12 Surge suppression varistors; 16.1 flexible cords)

  • Lighting
    • Luminaires, fixed, general purpose
      (Except for: Screw diameter>6.0mm; Clip-mounted luminaires; UV radiation)

    • Recessed luminaires
      (Except for: Screw diameter>6.0mm; Clip-mounted luminaires; UV radiation)

    • Portable general purpose luminaires
      (Except for: Screw diameter>6.0mm; Clip-mounted luminaires; UV radiation)

    • Floodlights
      (Except for: Screw diameter>6.0mm; Clip-mounted luminaires; UV radiation)

    • Portable luminaires for garden use
      (Except for:Screw diameter>6.0mm; Clip-mounted luminaires; UV radiation)

    • Handlamps
      (Except for: Screw diameter>6.0mm; Clip-mounted luminaires; UV radiation)

    • Portable child-appealing luminaires
      (Except for: 6.4 small removable parts test; Screw diameter>6.0mm; Clip-mounted luminaires; UV radiation)

    • Nightlights
      (Except for: Screw diameter>6.0mm; Clip-mounted luminaires; UV radiation)

    • Lighting chains
      (Except for: 12.3 Lampholder protection against electrical shock; Screw diameter>6.0mm; Clip-mounted luminaires; UV radiation)

    • Self-ballasted lamps

    • A.C. supplied electronic ballasts of tubular fluorescent lamps

    • Ballasts for tubular fluorescent lamps

  • Household and Similar Equipment
    • General requirements
      (Except for: Three-phase product and single-phase product with rating >3KA; 21.2 scratched、22.16 Automatic cord reels; 22.32 aging of natural or synthetic rubber corrosion; 22.46 Software evaluation;22.48 Back siphonage、23.3 flexing test; Capacitors(24.1.1,Annex F); Switch(24.1.3,Annex H); Controls(24.1.4); Appliance coupler (24.1.15); 29.1 Impulse voltage test)

    • Water suction cleaning appliances
      (Except for: 15.101 impact and free fall; 21.101-105 the abrasion resistance test; 22.102 proof cooling test; limited items on general requirements)

    • Electric dry irons
      (Except for: 21.101 free-drop, 22.105 Cordless electric iron plug, limited items on general requirements)

    • Electric shavers
      (Except for: limited items on general requirements)

    • Grills, toasters and similar portable cooking appliances
      (Except for: limited items on general requirements)

    • Electric kitchen machines
      (Except for: limited items on general requirements)

    • Appliance for heating liquids
      (Except for: limited items on general requirements)

    • Appliances for skin or hair care
      (Except for: helmet-type hairdryer; limited items on general requirements)

    • Food freezers
      (Except for: appliances containing compressor;15.102 filled with water test;22.101 lampholder test; Annex C、D、AA、BB; limited items on general requirements)

    • Battery chargers
      (Except for: limited items on general requirements)

    • Room heaters
      (Except for: ceiling mounted heater; heater for mounting at high level; limited items on general requirements)

    • Range hoods
      (Except for: limited items on general requirements)

    • Massage appliances
      (Except for: Massage belt; limited items on general requirements)

    • Electric pumps for liquids
      (Except for: limited items on general requirements)

    • Towel rails
      (Except for: limited items on general requirements)

    • Oral hygiene appliances
      (Except for: limited items on general requirements)

    • Cleaning appliances
      (Except for: 21.101-105 the abrasion resistance test; limited items on general requirements)

    • Insect killers
      (Except for: 32 Radiation, toxicity and similar hazards, limited items on general requirements)

    • Air-cleaning appliances
      (Except for: 32 Radiation, toxicity and similar hazards, limited items on general requirements)

    • Electric fans
      (Except for: limited items on general requirements)

    • Foot warmers and heating mats
      (Except for:21.101 compressed test; 21.102 insulation endurance test; 30.101 spark ignition test; limited items on general requirements)

    • Fabric steamers
      (Except for: 21.101~105 Current carrying tube test; limited items on general requirements)

    • Power transformers and power supply units
      (Except for: Three-phase product and single-phase product with rating > 500VA; 16.3 drop test, 19.9 oxygen bomb test, 19.10 Abrasion resistance test)

Shenzhen Anbotek Compliance Laboratory Limited

1/F., Building 1, SEC Industrial Park, South of Neihuan Road & East of Gangwan Road, Nanshan District, Shenzhen, Guangdong, China

Tel: 0755-26064492
Fax: 0755-26014772

As detailed in the Laboratory Accreditation Certificate No. CNAS L3503 dated 24.6.2011 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 24.6.2011.

  • Information technology equipment (Except for capacitance, Size greater than 1000×1000×1000mm product, overload, Endurance test, Measurement of transient voltages, Material group and comparative tracking index, Semiconductor devices,(Annex U)Insulated winding wires for use without interleaved insulation, Tests on coated printed boards, Enclosed and sealed parts, Spacings filled by insulating compound, Component external terminations, AC power supply cords, Cathode ray tubes, Flammable liquids, Radiation (Annex A), Flammability test used Bunsen burner, greater than 5kV electric strength, Impulse test, Voltage surge test , Impulse test)

  • Audio Video and similar electronic apparatus (Except for radiation, Heat resistance of insulating material, Endurance test for wound components with insulated winding wires without additional interleaved insulation, energy of discharge, product larger than 1000×1000×1000mm, Surge test, Vibration test, Only measure Clearances and creepage distance dimension between components, External flexible cords, External flexible cord torque test, greater than 2Nm torque test, Flammability test used Bunsen burner)

  • Machinery (Accredited only for Continuity of the protective bonding circuit, Insulation resistance, Voltage test)

  • Power transformers, power supplies, reactors and similar products (Except for Discharge, Vibration, Torque, IP code test higher than IP20, Size greater than 1000×1000×1000mm product, Greater than 5KV, Scratch test, External flexible cables or cords test, Only screws torque(greater than 1.2N), Multilayer thin sheets of insulated material, Mandrel test, Resistance to tracking, Resistance to rusting)

  • Laboratory equipment (Except for max. pressure of liquid, high pressure leakage and breaked, low pressure leakage, overpressure safety devices, Ionization devices, Ultraviolet radiation, microwave radiation, sonic, ultrasonic pressure, laser Source, Poisonous and injurious gases, protection against explosion and implosion, CRT explosion)

  • UPS products (Except for capacitance, Size greater than 1000×1000×1000mm product, overload, Endurance test, Measurement of transient voltages, Material group and comparative tracking index, Semiconductor devices, (Annex U) Insulated winding wires for use without interleaved insulation, Tests on coated printed boards, Enclosed and sealed parts, Spacings filled by insulating compound, Component external terminations, AC power supply cords, Cathode ray tubes, Flammable liquids, Radiation, Annex A Flammability test used Bunsen burner, greater than 5kV, Impulse test)

  • Household and similar electrical appliances :-
    • Vacuum cleaners and water suction cleaning appliances (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, additional mechanical strength requirements for cleansers)

    • Warming plates and similar appliances (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers)

    • Grills, toasters and similar portable cooking appliances (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, rotary grill, Resistance to rusting)

    • Appliances for heating liquids (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, abnormal operation for pressure-relief devices, appliance coupler of cordless kettles)

    • Appliances for skin or hair care (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, temperature test for 1500 revolutions of appliances incorporating a swivel connection, Restricted heat dissipation, Helmet-type hairdryers)

    • Refrigerating appliances, ice-cream appliances and ice-makers (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, compressed appliances with flammable refrigerants ,mechanical strength)

    • Ultraviolet and infrared radiation appliance (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, construction of UV appliances incorporating a timer)

    • Room heaters (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, heating)

    • Massage appliances (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers)

    • Commercial electric cooking ranges,ovens, hobs and hob elements (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, capillary tube of thermostat )

    • Commercial electric deep fat fryers (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, capillary tube of thermostat, Resistance to heat and fire of filter)

    • Commercial electric griddles and griddle grills (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, capillary tube of thermostat )

    • Commercial electric forced convection ovens, steam cookers and steam-convection ovens (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, capillary tube of thermostat )

    • Commercial electric boiling pans (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, pressure relief device, capillary tube of thermostat )

    • Commercial electric grillers and toasters (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, capillary tube of thermostat )

    • Commercial electric appliances for keeping food and crockery warm (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, capillary tube of thermostat )

    • Commercial electric bains-marie (Except for: Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, capillary tube of thermostat )

    • Commercial electric kitchen machines (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, Appliances for washing and drying foodstuffs, rotation speed of Knife sharpeners, capillary tube of thermostat )

    • Air-cleaning appliances (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers)

    • Commercial dispensing appliances and vending machines (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, construction of appliances having pressurized containers)

    • Fans (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers)

    • Service machines and amusement machines (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, resistance to rusting)

    • Humidifier (Except for: IP protection, EMC requirements for appliances having a an off position by electronic disconnection, solid insulation has strength to prevent penetration by sharp implements., deposition of pollution for supplementary insulation and reinforced insulation, water mains, components, earth terminal, creepage distance, radiation, toxicity and similar hazards, Annex F capacitors, Annex H switches, Annex J coated printed circuit boards, Annex R software , Annex G safety isolating transformers, construction of appliances intended to be connected to the water mains)

  • Luminaires :-
    • Fixed general purpose luminaries
    • Recessed luminaires
    • Portable general purpose luminaires
    • Handlamps(Except for construction of handlamp with a flexible cable or cord, resistance to heat for handlamps having a handle or shell of flexible material)
    • Portable luminaires for children
    • Stage lighting
    • Lighting chains
    • Self-ballasted lamps(Accredited only for on E27 Cap self Ballast Lamp)
    • Electronic ballasts for fluorescent lamps (Except for: Screws have diameter >3.6mm, abnormal conditions, Asymmetric pulse test, Asymmetric power test, open filament test)
    • Electronic controlgear for LED modules (Except for: Screws have diameter >3.6mm,Annex I test)
    • LED modules (Except for: Screws have diameter >3.6mm,Annex I test)
  • Medical device :-
    • Medical electrical Power Supply (Except for:Three phase Medical Power supply,17 h Defibrillation-proof test)
    • Beauty instrument (Except for:Three phase Medical Power supply,17 h Defibrillation-proof test)

Shenzhen AOV Testing Technology Co., Ltd.

2-6/F., No.5, Yuantou Lane, Tanglang, Taoyuan Street, Nanshan District, Shenzhen, Guangdong, China

Tel: 0755-86008000
Fax: 0755-86008282

As detailed in the Laboratory Accreditation Certificate No. CNAS L2631 dated 29.4.2011 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 29.4.2011.

  • Household appliances :-

    • Shavers, hair clippers and similar appliances
    • Deep fat fryers, frying pans and similar appliances
    • Kitchen machines
    • Appliances for skin or hair care
    • Clocks
    • Battery chargers
    • Massage appliances
    • Oral hygiene appliances
    • Electrical appliance or use with aquarium and garden ponds
    • Fans
    • Humidifiers
      (Above products testing excluding clauses 14,15.1, humidity test for Volume≧100x100x100cm, 19.11.4, 21.2, 22.1, 22.3, 22.32(Oxygen bomb), 22.46(Software evaluation, 24.1.1, 24.1.3, 24.1.4, 24.1.5, 24.1.6, 25.14, 31, 32.)
  • Luminaires :-

    • Fixed general purpose luminaires
    • Portable general purpose luminaires
    • Floodlights
    • Luminaires with built-in transformers or converters for filament lamps
    • Portable luminaires for children
    • Aquarium luminaires
    • Mains socket-outlet mounted nightlights
    • Luminaires with limited surface temperatures
      (Above products testing excluding vibration test for rough service luminaries, UV radiation test, dustproof test (degree IP5X-IP6X), waterproof test (degree IPX5-IPX8), torque test except screw, power cord curve test, resistance to rusting.)
    • Lamp controlgear
    • d.c. or a.c. supplied electronic controlgear for LED modules
    • LED modules for general lighting
  • Audio, video and similar electronic apparatus (Excluding 3-Phase appliances, 6 hazardous radiation, 7.2 heat resistance of insulating material, 10.1 surge test, 12.1.2 vibration test, 13.3.4 measurement of transient voltages, 14 components, 18 mechanical strength of picture tubes and protection against the effects of implosion, Annex G flammability test, Annex A additional requirements for apparatus with protection against splashing water, Annex B apparatus to be connected to the telecommunication networks, Annex H insulated winding wires for use without interleaved insulation, Annex L additional requirements for electronic flash apparatus for photographic purposes.)

  • Information technology equipment (Excluding 3-Phase appliances, 1.5.3 thermal controls, 1.5.6 capacitors bridging insulation, 1.5.7 resistors bridging insulation, 1.5.9 surge suppressors, 2.3 TNV circuits, 2.10.3.9 measurement of transient voltages, 4.2.8 mechanical strength of cathode ray tubes, 4.2.9 high pressure lamps, 4.3.13 radiation, 6 connection to telecommunication networks, 7 connection to cable distribution systems, Annex A flammability test used Bunsen burner, Annex K thermal controls, Annex U insulated winding wires for use without interleaved insulation, Annex AA mandrel test.)

Shenzhen BCTC Testing Co., Ltd.

BCTC Building & 1-2/F., East of B Building, Pengzhou Industrial Park, Fuyuan 1st Road, Qiaotou, Fuyong Street, Bao'an District, Shenzhen, Guangdong, China

Tel: 0755-32997622
Fax: 0755-36882552

As detailed in the Laboratory Accreditation Certificate No. CNAS L6046 dated 2018-12-19 and the attached appendices for the scope of accreditation and excluding items issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 2018-12-19.

Classes of Electrical Products ... Standards Applicable

Shenzhen BST Technology Co., Ltd.

Building 23-24, Zhieng Industrial Park, Guankou 2nd Road, Nantau, Nanshan District, Shenzhen, Guangdong, China

Tel: 0755-26505832
Fax: 0755-26504032

As detailed in the Laboratory Accreditation Certificate No. CNAS L3574 dated 8.7.2008 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 23.3.2016

  • Household and similar electrical appliances

    • General requirement (Excluding Transient over voltages, oxygen bomb and Fuchsine test (22.32)、software (22.46), components (24), radiation toxicity and similar hazards (32))
    • Shavers, hair clippers and similar appliances (Excluding Helmet type apparatus)
    • Kitchen machines
    • Appliance for heating liquids
    • Appliances for skin or hair care
    • Battery chargers
    • Massage appliances
    • Air-cleaning appliances
    • Electric fans
    • Humidifiers
  • Luminaries

    • General requirements and tests (Excluding Vibration test(4.20), IPX8, Rectification effect of metal halide lamp)
    • Fixed general purpose luminaries
    • Recessed luminaries
    • Portable general purpose luminaries
    • Lighting chains
    • Floodlights
    • Handlamps
    • Air-handling luminaires
    • Portable luminaires for garden use
    • Portable luminaires for children
    • Ground recessed luminaires (Excluding static load resistance, Anti-torque and shear load)
    • Luminaires for aquarium
  • Emergency lighting (Excluding Vibration test(4.20), UV radiation test(4.24 ) and Annex P, Functional safety(16), Conversion operations(17), High temperature operation(18), Battery chargers for self-contained emergency luminaires(19))

  • Self-ballasted lamps for general lighting services (Including test E27, E14, GU10 only)

  • Self-ballasted LED-lamps (Including test E27, E14, GU10 only)

  • Photobiological safety of lamps and lamp systems (Including test for Wavelength range 200nm-800nm only)

  • Double-capped LED lamps (Including test for lamp interchangeability, size only)

  • Lamp control gear

    • General and safety requirements (Excluding Annex A.2 of 10.1 high frequency leakage current)
    • d.c. or a.c. supplied electronic step-down converters for filament lamps
    • a.c. supplied electronic ballasts for fluorescent lamps
    • d.c. supplied electronic ballasts for general lighting
    • d.c. supplied electronic ballasts for emergency lighting (Excluding (29) high frequency leakage current, (16) lamp current and ballast lumen factor (BLF) , (18) Maximum current in any lead (with cathode preheating))
    • Ballasts for fluorescent lamps
  • Power transformers, power supply units and similar products

    • General requirements and tests (Excluding 19.9 oxygen bomb test, 20 Component)
    • Safety isolating transformers
    • Transformers and power supplies for toys
  • Audio, video and similar electronic apparatus (Excluding Clause 6 Radiation, Clause 8.17 insulated winding wires for use without interleaved insulation, Clause 8.22 Thin sheet insulation material, Annex J Alternative method for determining minimum clearances, Clause 14.2 Capacitor; Clause14.5 Protection device, Clause 14.6 Switch, Clause 14.11 Photocoupler, Clause 14.12 VDR test, Clause 16.1 Power supply cord, Clause 18 Mechanical strength of picture tubes and protection against the effects of implosion, Annex A Additional requirements for apparatus with protection against splashing water (IPX7,IPX8), Annex H Insulated winding wires for use without interleaved insulation, Annex L Additional requirements for electronic flash apparatus for photographic purposes, Annex Zx Protection against excessive sound pressure from personal music players)

  • Information technology equipment (Excluding Clause 1.5 component, Clause 2.3.5 working voltage generated from outside, Annex G Alternative method for determining minimum clearances, Clause 4.2.8 Mechanical strength of picture tubes, 4.2.9 Antenna positioners, Clause 4.3.12 Flammable Liquid, Clause 4.3.13 Radiation, Clause 6.2.2.1 impulse test, Clause 7.4.3 Impulse test, Annex A.3 Hot flaming oil test, Annex G Alternative method for determining minimum clearance, Annex K Thermal controls, Annex T Guidance on protection against ingress of water (IPX7,IRX8), Annex U Insulated winding wires for use without interleaved insulation, Annex Q Voltage dependent resistors (VDRs), Annex CC Evaluation of integrated circuit (IC) current limiters)

Shenzhen CTB Testing Technology Co., Ltd.

1&2/F., Building A, No. 26, Xinhe Road, Xinqiao, Xinqiao Street, Bao’an District, Shenzhen, Guangdong, China

Tel: 086-13662574496

As detailed in the Laboratory Accreditation Certificate No. CNAS L9438 dated 15.03.2019 and the attached appendices for the scope of accreditation and excluding items issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 15.03.2019.

Classes of Electrical Products ... Standards Applicable

Shenzhen CTL Testing Technology Co., Ltd.

1/F., -A, Baisha Technology Park, No. 3011, Sha hexi Road, Nanshan District, Shenzhen, Guangdong, China

Tel: 0755-89486149
Fax: 0755-26636041

As detailed in the Laboratory Accreditation Certificate No. CNAS L7497 dated 15.02.2015 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 15.02.2015

  • Household and Similar Equipment:
    • General requirements;
    • Battery chargers (Excluding IP class, EMC, solid insulation, IPX1-7, pressure, oxygen bomb and ceramic magenta, software, water pressure, backsiphonage, coating thickness)
  • Lighting
    • Fixed general purpose luminaires (Excluding torque of lamp cap test, humidity test for product volume larger than 50cm x 60cm x 70cm)
    • Recessed luminaires (Excluding torque of lamp cap test, humidity test for product volume larger than 50cm x 60cm x 70cm)
    • Ballast (Excluding HF leakage, humidity test for product volume larger than 50cm x 60cm x 70cm, HF electrospark)
    • D.C. or A.C. supplied electronic controlgear for LED modules (Excluding HF leakage, humidity test for product volume larger than 50cm x 60cm x 70cm, HF electrospark)
  • Electronics, Entertainment
    • Amplifiers (Excluding humidity test for product volume larger than 50cm x 60cm x 70cm)
    • Audio equipment (Excluding humidity test for product volume larger than 50cm x 60cm x 70cm)
    • Karaoke equipment (Excluding humidity test for product volume larger than 50cm x 60cm x 70cm)
    • Television (Excluding humidity test for product volume larger than 50cm x 60cm x 70cm)
    • Video equipment (Excluding humidity test for product volume larger than 50cm x 60cm x 70cm)
  • Information technology equipment
    • Copying machine (Excluding humidity test for product volume larger than 50cm x 60cm x 70cm)
    • Data processing equipment (Excluding humidity test for product volume larger than 50cm x 60cm x 70cm)
    • Facsimile machine (Excluding humidity test for product volume larger than 50cm x 60cm x 70cm)
    • Modem (Excluding humidity test for product volume larger than 50cm x 60cm x 70cm)
    • Telephone answering machines (humidity test for product volume larger than 50cm x 60cm x 70cm)
    • Typewriter (Excluding humidity test for product volume larger than 50cm x 60cm x 70cm)
    • Visual display units for computer (Excluding humidity test for product volume larger than 50cm x 60cm x 70cm)

Shenzhen Emtek Co., Ltd.

Building 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China

Tel: 86-755-26954280
Fax: 86-755-26954282

As detailed in the Laboratory Accreditation Certificate No. CNAS L2291 dated 29.10.2013 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 29.10.2013.

  • Household and similar electrical appliance (Excluding socket-outlet forces, automatic cord reels, oxygen bomb, component, coated layers, proof tracking index test, radiation, toxicity and similar hazards)
    • Fans (Excluding hardness for fan blades)
    • Grills, toasters and similar portable cooking appliances
    • Kitchen machines
    • Room heaters (Excluding built-in heaters)
    • Appliances for skin or hair care (Excluding helmet-type hairdryer)
    • Massage appliances
    • Appliances for heating liquids
    • Battery chargers
    • Electric irons
    • Stationary cooking ranges, hobs, ovens
    • Shavers, hair clippers
    • Vacuum cleaners and water-suction cleaning appliances (Excluding mechanical strength for current-carrying hoses)
    • Instantaneous water heaters (Excluding water pressure test, pressure relief test, water temperature test, water pressure test, excessive pressure test)
    • Oral hygiene appliances
    • Insect killers
    • Air-cleaning appliances (Excluding ozone test)
    • Fixed immersion heaters
    • Portable immersion heaters
    • Humidifiers
    • Food waste disposers
    • Portable heating tools
    • Vaporizer (Excluding abnormal test)
    • Floor treatment machines
    • Towel rails
    • Fabric steamers
  • Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
  • Luminaires (Excluding UV radiation test, short-circuit protection test, proof tracking index test)
    • Fixed general purpose luminaires
    • Portable general purpose luminaires
    • Luminaires for stage lighting, television film and photographic studios (outdoor and indoor)
    • Lighting chains
    • Luminaires for emergency lighting
    • Self-ballasted lamps for general lighting services(Excluding interchangeability)
    • LED modules for general lighting (Excluding torque test excluding screw, proof tracking index test)
    • Recessed luminaires
    • Floodlights
    • Luminaires with built-in transformers for filament lamps
    • Portable luminaires for garden use
    • Handlamps
    • Portable child-appealing luminaires
    • Luminaires for aquarium
    • Nightlights
  • Power transformers, power supply units and similar appliances (Excluding torque test excluding screw, tumbling barrel test, power cord test, resistance to rusting, proof tracking index test, multiple layer insulation winding wires test, abrasion resistance test for coating layers)
    • Safety isolating transformers for general use
    • Transformers for toys
    • Transformers for switch mode power supplies
    • Control transformers
    • Isolating transformers for general use
    • Shaver transformers and shaver power supply units
    • Bell and chime transformers
    • Constant voltage transformers
    • Isolating transformers for the supply of medical
    • Transformers for switch mode power supply units
  • Lamp controlgear (Excluding torque test excluding screw, proof tracking index test)
    • D.C. or A.C. supplied electronic step-down convertors for filament lamps
    • A.C. supplied electronic ballasts for fluorescent lamps
    • D.C. or A.C. supplied electronic ballasts for discharge lamps
    • D.C. or A.C. supplied electronic controlgear for LED modules
  • Uninterruptible power systems (UPS)
    (Excluding component, insulated winding wires for use without interleaved insulation, working voltage generated from outside, impulse test, power supply cord)
  • Audio, Video and similar electronic apparatus (Excluding radiation, insulated winding wires for use without interleaved insulation, thin sheet insulation material, capacitor, protection device, photocoupler, switch, voltage dependent resistor (VDR) test, vibration;power supply cord, mechanical strength of picture tubes and protection against the effects of implosion, alternative method for determining minimum clearances)
    • Amplifiers
    • Audio equipment
    • Karaoke equipment
    • Television
    • Video equipment
  • Information technology equipment (Excluding component, working voltage generated from outside, insulated winding wires for use without interleaved insulation, mechanical strength of picture tubes, radiation, flammable liquid, impulse test, alternative method for determining minimum clearances)
    • Copying machine
    • Data processing equipment
    • Facsimile machine
    • Modem
    • Telephone answering machines
    • Typewriters
    • Visual Display Units for computer

Shenzhen Global Test Service Co., Ltd.

Building 7, DCC Cultural and Creative Garden, No.98, Pingxin North Road, Shangmugu, Pinghu Street, Longgang District, Shenzhen, Guangdong, China

Tel: +86 755 2670 2000

As detailed in the Laboratory Accreditation Certificate No. CNAS L8169 dated 02.12.2020 and the attached appendices for the scope of accreditation and excluding items issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 02.12.2020.

Classes of Electrical Products ... Standards Applicable

Shenzhen HUAK Testing Technology Co., Ltd.

F1-008, Taiyi Building, No.1, Haicheng West Road, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China

Tel: 86-0755-23029901
Fax: 86-0755-23029901

As detailed in the Laboratory Accreditation Certificate No. CNAS L9589 dated 10.1.2017 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 10.1.2017.

  • Household and Similar Equipment
    • General requirements (Excluding test for protection against harmful ingress of water, EMC test, accessible parts of solid insulation, oxygen bomb and fuchsine tests, software, water pressure, backsiphonage of non-potable water)
    • Appliances for heating liquids (Excluding test for protection against harmful ingress of water, EMC test, accessible parts of solid insulation, oxygen bomb and fuchsine tests, software, water pressure, backsiphonage of non-potable water)
    • Appliances for skin or hair care (Excluding test for protection against harmful ingress of water, EMC test, accessible parts of solid insulation, oxygen bomb and fuchsine tests, software, water pressure, backsiphonage of non-potable water, helmet-type hairdryer, heater for detachable curlers, appliances incorporating a swivel connection)
    • Battery chargers (Excluding test for protection against harmful ingress of water, EMC test, accessible parts of solid insulation, oxygen bomb and fuchsine tests, software, water pressure, backsiphonage of non-potable water)
    • Room heaters (Excluding test for protection against harmful ingress of water, EMC test, accessible parts of solid insulation, oxygen bomb and fuchsine tests, software, water pressure, backsiphonage of non-potable water)
    • Electric Fans (Excluding test for protection against harmful ingress of water, EMC test, accessible parts of solid insulation, oxygen bomb and fuchsine tests, software, water pressure, backsiphonage of non-potable water)
  • Lighting
    • General requirements (Excluding rough service luminaires, rough service luminaires - vibration requirements, metal halide lamps)
    • Luminaires, fixed, general purpose (Excluding rough service luminaires, rough service luminaires - vibration requirements, metal halide lamps)
    • Recessed luminaires (Excluding rough service luminaires, rough service luminaires - vibration requirements, metal halide lamps)
    • Luminaires for road and street lighting (Excluding rough service luminaires, rough service luminaires - vibration requirements, metal halide lamps)
    • Portable general purpose luminaires (Excluding rough service luminaires, rough service luminaires - vibration requirements, metal halide lamps)
    • Floodlights (Excluding rough service luminaires, rough service luminaires - vibration requirements, metal halide lamps)
    • Lighting chains (Excluding rough service luminaires, rough service luminaires - vibration requirements, metal halide lamps)
    • Luminaires for emergency (Excluding rough service luminaires, rough service luminaires - vibration requirements, metal halide lamps)
    • Self-ballasted LED lamps
    • Self-ballasted lamps (Only for E14,E26,E27,B22d,GU10 lamp caps)
    • LED modules for general lighting
    • Lamp controlgear
    • Battery supplied electronic controlgear for emergency lighting (self-contained) (Excluding Lamp current, Maximum current in any lead (with cathode preheating))
    • D.C. or A.C. supplied electronic controlgear for LED modules
  • Power transformers, power supplies, reactors and similar products
    • Power transformers, power supplies, reactors and similar products (Only test output < 50V, 400VA , excluding ageing properties of rubber, scratch test, mandrel test)
    • Safety isolating transformers and power supply units incorporating safety isolating transformers (Only test output < 50V, 400VA , excluding ageing properties of rubber, scratch test, mandrel test)
    • Switch mode power supply units and transformers for switch mode power supply units (Only test output < 50V, 400VA , excluding ageing properties of rubber, scratch test, mandrel test)
  • Electronics, Entertainment
    • Audio, Video and similar electronic appratus (Excluding Three phase voltage supply system, Heat resistance of insulating material, Insulated winding wires of wound component, Non-separable thin sheet material, Measurement of transient voltages, Capacitors and RC-units, Protective devices, Switches, Optocouplers , Surge suppression varistors)
  • Information technology equipment

    • Information technology equipment (Excluding thermal controls, capacitors bridging insulation, surge suppressors, abrasion resistance test, cathode ray tubes)

Shenzhen Huatongwei International Inspection Co., Ltd.

Huatongwei Building, Keji’nan 12th Road, High-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, China

Tel: 86-755-26748078
Fax: 86-755-26748077

As detailed in the Laboratory Accreditation Certificate No. CNAS L1225 dated 01.03.2012 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 31.05.2013.

  • Audio, video and similar electronic apparatus (Excluding component test, vibration, CRT exploded)
  • Information technology equipment (Excluding component, A.C. power supply cords, arcing, hot wire ignition, hot flaming oil test, sound pressure test)
  • Household and similar electrical appliances

    • General requirements (Excluding automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Appliances for heating liquids (Excluding automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Electric fans (Excluding for duct fans, automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Massage appliances (Excluding sitting with foot massagers, automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Battery chargers (Excluding 21.102: vibration test;automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Appliances for skin or hair care (Excluding helmet-type hairdryers, swivel connection rotated test, needle-flame test, automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Room heaters (Excluding automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Humidifiers (Excluding water pressure test, automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Service machines and amusement machines (Excluding power cord flexing test, components, salt mist test, automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Clocks (Excluding automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Kitchen machines (Excluding slicers, food mixers, food processors, automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Oral hygiene appliances (Excluding automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Electrical appliances for use with aquariums and garden ponds (Excluding automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Vaporizers (Excluding automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
    • Portable immersion heaters (Excluding automatic cord reels test, resistant to ageing for rubber part test, software reliability test, resistant to back siphonage test and 3-phase device)
  • Medical Electrical Equipment

    • General Requirements for Safety (Excluding expelled parts, acoustic energy (including infra-red and ultrasound), pressure vessels and parts, radiation, AP&APG device, biocompatibility, alarm system)
    • Blankets, pads and mattresses, intended for heating in medical use (Excluding radiation, AP&APG device, biocompatibility)
    • Non-invasive sphygmomanometers
    • Medical electrical equipment and medical electrical systems used in the home healthcare environment (Excluding shock, vibration)
    • Electrical thermometers (non-predictive and predictive)
    • Electrical thermometers for continuous measurement
    • Infra-red ear thermometers (Excluding clinical repeatability)
  • Luminaires

    • General requirements (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Fixed general purpose luminaires (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Portable general purpose luminaires (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Floodlight (Excluding wind-resistance test, metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Recessed luminaires (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Self-ballasted lamps for general lighting services (Including E14、E26、E27 self-ballasted lamps only)
    • Electronic controlgear for lumininaire (Excluding heating test for winding of ballaster, d>6mm screws torque test, resistance to rusting test)
    • Electronic control gear for LED modules (Excluding vibration test, metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Luminaires for road and street lighting (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Self-ballasted LED lamps for general lighting services by voltage > 50V
    • D.C. or A.C. supplied electronic control gear for LED modules
    • LED modules for general lighting
    • Luminaires with built-in transformers or convertors for filament lamps (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Portable luminaires for garden use (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Handlamps (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Photo and film luminaires (non-professional) (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Portable luminaires for children (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Aquarium luminaires (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Nightlights (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Luminaires for cold cathode tubular discharge lamps (neon tubes) and similar equipment (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Luminaires for stage lighting, television and film studios (outdoor and indoor) (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Air-handling luminaires (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Luminaires for emergency lighting (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Extra low voltage lighting systems for filament lamps (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
    • Luminaires with limited surface temperature (Excluding metal halide luminaire, clip-mounted luminaire, lamp holder pressure test, bending moments test, d>6mm screws torque test, resistance to rusting test, vibration test, UV test, protection for dust ingress IP6X test, protection for water ingress IPX6, IPX8)
  • Electrical Toys (Excluding metal steeliness tes, radiation, toxicity for toy with laser and radiant diode)
  • Power transformers, power supply units and similar products

    • General requirements and tests (Excluding protection for dust ingress IP6X test, protection for water ingress IPX8, three phase appliance, components, resistance to rusting)
    • Safety isolating transformers (Excluding protection for dust ingress IP6X test, protection for water ingress IPX8, three phase appliance, components, resistance to rusting)
  • Transformers and power supplies for toys (Excluding protection for dust ingress IP6X test, protection for water ingress IPX8, three phase appliance, components, resistance to rusting)

Shenzhen Huaxia Testing Technology Co., Ltd.

1/F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua New District, Shenzhen, Guangdong, China

Tel: (86) 755-26648642
Email: szcqa@cqa-cert.com

As detailed in the Laboratory Accreditation Certificate No. CNAS L5785 dated 08.10.2022 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment CNAS dated 12.10.2022.

Classes of Electrical Products ... Standards Applicable

Shenzhen LCS Compliance Testing Laboratory Ltd.

Room 101/201, Building A, and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao'an District, Shenzhen, Guangdong, China

Tel: 86-755-82591330
Fax: 86-755-82591332

As detailed in the Laboratory Accreditation Certificate No. CNAS L4595 dated 15.01.2020 and the attached appendices for the scope of accreditation and excluding items issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 31.03.2020.

Classes of Electrical Products ... Standards Applicable

Shenzhen Microtest Co., Ltd.

101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Road, Xinhe Community, Fuhai Subdistrict, Baoan District, Shenzhen, Guangdong, China

Tel: 13425151596

As detailed in the Laboratory Accreditation Certificate No. CNAS L5868 dated 20.11.2020 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 20.11.2020.

Classes of Electrical Products ... Standards Applicable

Shenzhen NTEK Testing Technology Co., Ltd.

1/F, Building E, Fenda Science Park, Sanwei, Xixiang, Bao’an District, Shenzhen, Guangdong, China

Tel: 86-0755-61155918
Fax: 86-0755-61156599

As detailed in the Laboratory Accreditation Certificate No. CNAS L5516 dated 04.09.2014 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 04.09.2014.

  • Household and Similar Equipment :-
    • Appliances for skin or hair care (Excluding IP class, solid insulation, dust proof, pressure, oxygen bomb, software, water pressure, backsiphonage, coated or uncoated steel, Annex A, Annex F, Annex J, Annex K, Annex M, Annex R, helmet-type hairdryer)
    • Electric hair dryers (Excluding IP class, solid insulation, dust proof, pressure, oxygen bomb, software, water pressure, backsiphonage, coated or uncoated steel, Annex A, Annex F, Annex J, Annex K, Annex M, Annex R, helmet-type hairdryer)
    • Battery chargers (Excluding IP class, solid insulation, dust proof, pressure, oxygen bomb, software, water pressure, backsiphonage, coated or uncoated steel, Annex A, Annex F, Annex J, Annex K, Annex M, Annex R)
  • Lighting
    • Luminaires, fixed, general purpose (Excluding screws not made of soft metal test, resistance to corrosion, UV radiation, short-circuit protection, IP degree test, humidity test of whose volume exceed 100cm×100cm×100cm, endurance test of whose volume exceed 100cm×100cm×100 cm, screw terminals, screwless terminals)
    • Recessed luminaires (Excluding screws not made of soft metal test, resistance to corrosion, UV radiation, short-circuit protection, IP degree test, humidity test of whose volume exceed 100cm×100cm×100cm, endurance test of whose volume exceed 100cm×100cm×100 cm, screw terminals, screwless terminals)
    • Portable general purpose luminaires (Excluding shear load test, screws not made of soft metal test, resistance to corrosion, UV radiation, short-circuit protection, IP degree test, humidity test of whose volume exceed 100cm×100cm×100cm, endurance test of whose volume exceed 100cm×100cm×100 cm, screw terminals, screwless terminals)
    • Self-ballasted LED lamps (Excluding interchangeability test other than E27,E14 lamp cap, protection against electric shock other than E27,E14 cap)
    • Self-ballasted lamps (Excluding interchangeability other than E14,E27 cap, protection against electric shock other than E14,E27 cap)
  • Electronics, Entertainment
    • Amplifiers (Excluding three phase products, heat resistance of insulating material, humidity conditioning (dimensions exceed 1m×1m×1m sample), insulated winding wires for use without interleaved insulation, bump test, Annex J Alternative method for determining minimum clearances, capacitor, protection device, switch, photocoupler, VDR test, fexible cords, Annex A Additional requirements for apparatus with protection against splashing water, Annex B Apparatus to be connected to the TELECOMMUNICATION NETWORKS, Annex H Insulated winding wires for use without interleaved insulation, Annex L Additional requirements for electronic flash apparatus for photographic purposes, Annex Zx Protection against excessive)
    • Audio equipment (Excluding three phase products, heat resistance of insulating material, humidity conditioning (dimensions exceed 1m×1m×1m sample), insulated winding wires for use without interleaved insulation, bump test, Annex J Alternative method for determining minimum clearances, capacitor, protection device, switch, photocoupler, VDR test, fexible cords, Annex A Additional requirements for apparatus with protection against splashing water, Annex B Apparatus to be connected to the TELECOMMUNICATION NETWORKS, Annex H Insulated winding wires for use without interleaved insulation, Annex L Additional requirements for electronic flash apparatus for photographic purposes, Annex Zx Protection against excessive)
    • Karaoke equipment (Excluding three phase products, heat resistance of insulating material, humidity conditioning (dimensions exceed 1m×1m×1m sample), insulated winding wires for use without interleaved insulation, bump test, Annex J Alternative method for determining minimum clearances, capacitor, protection device, switch, photocoupler, VDR test, fexible cords, Annex A Additional requirements for apparatus with protection against splashing water, Annex B Apparatus to be connected to the TELECOMMUNICATION NETWORKS, Annex H Insulated winding wires for use without interleaved insulation, Annex L Additional requirements for electronic flash apparatus for photographic purposes, Annex Zx Protection against excessive)
    • Television (Excluding three phase products, heat resistance of insulating material, humidity conditioning (dimensions exceed 1m×1m×1m sample), insulated winding wires for use without interleaved insulation, bump test, Annex J Alternative method for determining minimum clearances, capacitor, protection device, switch, photocoupler, VDR test, fexible cords, Annex A Additional requirements for apparatus with protection against splashing water, Annex B Apparatus to be connected to the TELECOMMUNICATION NETWORKS, Annex H Insulated winding wires for use without interleaved insulation, Annex L Additional requirements for electronic flash apparatus for photographic purposes, Annex Zx Protection against excessive)
    • Video equipment (Excluding three phase products, heat resistance of insulating material, humidity conditioning (dimensions exceed 1m×1m×1m sample), insulated winding wires for use without interleaved insulation, bump test, Annex J Alternative method for determining minimum clearances, capacitor, protection device, switch, photocoupler, VDR test, fexible cords, Annex A Additional requirements for apparatus with protection against splashing water, Annex B Apparatus to be connected to the TELECOMMUNICATION NETWORKS, Annex H Insulated winding wires for use without interleaved insulation, Annex L Additional requirements for electronic flash apparatus for photographic purposes, Annex Zx Protection against excessive)
  • Information technology equipment
    • Data processing equipment (Excluding thermal controls, capacitors bridging insulation, components in equipment for IT power distribution systems, surge suppressors, three phase equipment, humidity conditioning (dimensions exceed 1m×1m×1m sample), mains transient voltages, non-separable thin sheet material, coated printed boards, abrasion resistance test, 800N, cathode ray tubes, high pressure lamps, flammable liquids, radiation, hot flaming oil test, Annex B Overload, Annex G Alternative method for determining minimum clearance, Annex H Ionizing radiation, Annex K Thermal controls, Annex M Criteria for telephone ringing signals, Annex N Impulse test generators, Annex Q Voltage dependent resistors (VDRs), Annex T Guidance on protection against ingress of water, Annex U Insulated winding wires for use without interleaved insulation, Annex Y Ultraviolet light conditioning test, Annex AA Mandrel test, Annex CC Evaluation of integrated circuit (IC) current limiters, Annex Zx Significance of LAeq,T in EN 50332-1 and additional information)
    • Visual display units for computer (Excluding thermal controls, capacitors bridging insulation, components in equipment for IT power distribution systems, surge suppressors, three phase equipment, humidity conditioning (dimensions exceed 1m×1m×1m sample), mains transient voltages, non-separable thin sheet material, coated printed boards, abrasion resistance test, 800N, cathode ray tubes, high pressure lamps, flammable liquids, radiation, hot flaming oil test, Annex B Overload, Annex G Alternative method for determining minimum clearance, Annex H Ionizing radiation, Annex K Thermal controls, Annex M Criteria for telephone ringing signals, Annex N Impulse test generators, Annex Q Voltage dependent resistors (VDRs), Annex T Guidance on protection against ingress of water, Annex U Insulated winding wires for use without interleaved insulation, Annex Y Ultraviolet light conditioning test, Annex AA Mandrel test, Annex CC Evaluation of integrated circuit (IC) current limiters, Annex Zx Significance of LAeq,T in EN 50332-1 and additional information)

Shenzhen Southern LCS Compliance Testing Laboratory Ltd.

101-201, No.39 Building, Xialang Industrial Zone, Heshuikou Community, Matian Street, Guangming District, Shenzhen, China

Tel: 0755-29871520
Fax: 0755-29871521

As detailed in the Laboratory Accreditation Certificate No. CNAS L10160 dated 12.07.2019 and the attached appendices for the scope of accreditation and excluding items issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 17.03.2020.

Classes of Electrical Products ... Standards Applicable

Shenzhen United Testing Technology Co., Ltd.

2/F., Annex Building, Jiahuangyuan Tech Park, No.365, Baotian 1st Road, Tiegang, Xixiang Street, Bao’an District, Shenzhen, Guangdong, China

Tel: 13066967377

As detailed in the Laboratory Accreditation Certificate No. CNAS L6964 dated 03.07.2017 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 03.07.2017.

  • Household and Similar Equipment
    • General requirements
      (Except for: IP level; humidity test only for appliance with size less than 50cm x 60cm x70cm; 19.11.4 EMC; software evaluation, Rubber aging resistance)
    • Electric shavers
      (Except for: IP level; humidity test only for appliance with size less than 50cm x 60cm x70cm; 19.11.4 EMC; software evaluation, Rubber aging resistance)
    • Appliances for heating liquids
      (Except for: IP level; humidity test only for appliance with size less than 50cm x 60cm x70cm; 19.11.4 EMC; software evaluation, Rubber aging resistance)
    • Appliances for skin or hair care
      (Except for: IP level; humidity test only for appliance with size less than 50cm x 60cm x70cm; 19.11.4 EMC; software evaluation, Rubber aging resistance)
    • Electric fans
      (Except for: IP level; humidity test only for appliance with size less than 50cm x 60cm x70cm; 19.11.4 EMC; software evaluation, Rubber aging resistance)
    • Battery chargers
      (Except for: IP level; humidity test only for appliance with size less than 50cm x 60cm x70cm; 19.11.4 EMC; software evaluation, Rubber aging resistance)
    • Room heaters
      (Except for: IP level; humidity test only for appliance with size less than 50cm x 60cm x70cm; 19.11.4 EMC; 19.103 cover test; software evaluation, Rubber aging resistance)
    • Massage appliances
      (Except for: IP level; humidity test only for appliance with size less than 50cm x 60cm x70cm; 19.11.4 EMC; software evaluation, Rubber aging resistance)
    • Air-cleaning appliances
      (Except for: IP level; humidity test only for appliance with size less than 50cm x 60cm x70cm; 19.11.4 EMC; software evaluation, Rubber aging resistance)
    • Electric kitchen machines
      (Except for: IP level; humidity test only for appliance with size less than 50cm x 60cm x70cm; 19.11.4 EMC; software evaluation, Rubber aging resistance)
    • portable heating tools
      (Except for: IP level; humidity test only for appliance with size less than 50cm x 60cm x70cm; 19.11.4 EMC; software evaluation, Rubber aging resistance)
    • humidifiers
      (Except for: IP level; humidity test only for appliance with size less than 50cm x 60cm x70cm; 19.11.4 EMC; software evaluation, Rubber aging resistance)
  • Lighting
    • General requirements
      (Except for: 4.11.6 Electrical stresses of electro-mechanical contact systems; 4.12 Torque test on screw more than 6mm; 4.12.5 Screwed glands; 4.13.4 Rough service luminaires; 4.13.6 Mechanical strength of plug-ballast/transformers and mains socket outlet mounted luminaires; 4.18 Resistance to corrosion; 4.20 Rough service luminaires–Vibration Requirements; 4.24 Photobiological Hazards; 4.26 Short-circuit protection; 9.3 Humidity test ,and luminaire's dimension larger than 50 cm×60cm×70 cm; Annex G.3, G.4 weighted measuring network; Tubular fluorescent or other discharge lamp luminaire)
    • Luminaires, Fixed, general purpose
      (Except for: 4.11.6 Electrical stresses of electro-mechanical contact systems; 4.12 Torque test on screw more than 6mm; 4.12.5 Screwed glands; 4.13.4 Rough service luminaires; 4.13.6 Mechanical strength of plug-ballast/transformers and mains socket outlet mounted luminaires; 4.18 Resistance to corrosion; 4.20 Rough service luminaires–Vibration Requirements; 4.24 Photobiological Hazards; 4.26 Short-circuit protection; 9.3 Humidity test ,and luminaire's dimension larger than 50 cm×60cm×70 cm; Annex G.3, G.4 weighted measuring network; Tubular fluorescent or other discharge lamp luminaire)
    • Recessed luminaires
      (Except for: 4.11.6 Electrical stresses of electro-mechanical contact systems; 4.12 Torque test on screw more than 6mm; 4.12.5 Screwed glands; 4.13.4 Rough service luminaires; 4.13.6 Mechanical strength of plug-ballast/transformers and mains socket outlet mounted luminaires; 4.18 Resistance to corrosion; 4.20 Rough service luminaires–Vibration Requirements; 4.24 Photobiological Hazards; 4.26 Short-circuit protection; 9.3 Humidity test ,and luminaire's dimension larger than 50 cm×60cm×70 cm; Annex G.3, G.4 weighted measuring network; Tubular fluorescent or other discharge lamp luminaire)
    • Floodlights
      (Except for: 4.11.6 Electrical stresses of electro-mechanical contact systems; 4.12 Torque test on screw more than 6mm; 4.12.5 Screwed glands; 4.13.4 Rough service luminaires; 4.13.6 Mechanical strength of plug-ballast/transformers and mains socket outlet mounted luminaires; 4.18 Resistance to corrosion; 4.20 Rough service luminaires–Vibration Requirements; 4.24 Photobiological Hazards; 4.26 Short-circuit protection; 9.3 Humidity test ,and luminaire's dimension larger than 50 cm×60cm×70 cm; Annex G.3, G.4 weighted measuring network; Tubular fluorescent or other discharge lamp luminaire; IP, Static load test)
    • Portable general purpose luminaires
      (Except for: 4.11.6 Electrical stresses of electro-mechanical contact systems; 4.12 Torque test on screw more than 6mm; 4.12.5 Screwed glands; 4.13.4 Rough service luminaires; 4.13.6 Mechanical strength of plug-ballast/transformers and mains socket outlet mounted luminaires; 4.18 Resistance to corrosion; 4.20 Rough service luminaires–Vibration Requirements; 4.24 Photobiological Hazards; 4.26 Short-circuit protection; 9.3 Humidity test ,and luminaire's dimension larger than 50 cm×60cm×70 cm; Annex G.3, G.4 weighted measuring network; Tubular fluorescent or other discharge lamp luminaire)
    • Lighting chains
      (Except for: 4.11.6 Electrical stresses of electro-mechanical contact systems; 4.12 Torque test on screw more than 6mm; 4.12.5 Screwed glands; 4.13.4 Rough service luminaires; 4.13.6 Mechanical strength of plug-ballast/transformers and mains socket outlet mounted luminaires; 4.18 Resistance to corrosion; 4.20 Rough service luminaires–Vibration Requirements; 4.24 Photobiological Hazards; 4.26 Short-circuit protection; 9.3 Humidity test ,and luminaire's dimension larger than 50 cm×60cm×70 cm; Annex G.3, G.4 weighted measuring network; Tubular fluorescent or other discharge lamp luminaire; Mechanical strength of closed lamp string, Live test of metal wire or metal decoration, Checking security of lampholder contacts)
    • Handlamps
      (Except for: 4.11.6 Electrical stresses of electro-mechanical contact systems; 4.12 Torque test on screw more than 6mm; 4.12.5 Screwed glands; 4.13.4 Rough service luminaires; 4.13.6 Mechanical strength of plug-ballast/transformers and mains socket outlet mounted luminaires; 4.18 Resistance to corrosion; 4.20 Rough service luminaires–Vibration Requirements; 4.24 Photobiological Hazards; 4.26 Short-circuit protection; 9.3 Humidity test ,and luminaire's dimension larger than 50 cm×60cm×70 cm; Annex G.3, G.4 weighted measuring network; Tubular fluorescent or other discharge lamp luminaire; Portable lamp impact test)
    • Luminaires for emergency
      (Except for: 4.11.6 Electrical stresses of electro-mechanical contact systems; 4.12 Torque test on screw more than 6mm; 4.12.5 Screwed glands; 4.13.4 Rough service luminaires; 4.13.6 Mechanical strength of plug-ballast/transformers and mains socket outlet mounted luminaires; 4.18 Resistance to corrosion; 4.20 Rough service luminaires–Vibration Requirements; 4.24 Photobiological Hazards; 4.26 Short-circuit protection; 9.3 Humidity test ,and luminaire's dimension larger than 50 cm×60cm×70 cm; Annex G.3, G.4 weighted measuring network; Tubular fluorescent or other discharge lamp luminaire; Photometric distribution and luminance)
    • Self-ballasted lamps
      (Accredited only for E14, E26, E27, B22d Lamp cap)

      Self-ballasted LED-lamps for general lighting services by voltage>50V
      (Accredited only for E12, E14, E17, E26, E27, B22d Lamp cap)

      Double-capped LED lamps designed to retrofit linear fluorescent lamps – Safety specifications
      (Accredited only for G13 cap; Torque test after heat treatment only for tube length no more than 60cm)

      Self-ballasted lamps
      (Accredited only for Integrating sphere method and lamp max dimension < 200mm)

    • Lamp controlgear
      (Except for: Torque test on screw more than 6mm; resistance to fire of printed circuit board)
    • d.c. or a.c. supplied electronic controlgear for LED modules
      (Except for: Torque test on screw more than 6mm; Annex D; resistance to fire of printed circuit board)
    • Electronics, Entertainment
      (Except for: 8.18 b) vibration test; 10.1Surge Test; humidity test only for appliance with size less than 50cm x 60cm x70cm; 12.1.2 Vibration; 13.3.4 Transient voltages; 20.1.3 printed circuit boards)
    • Information technology equipment (Humidity test only for appliance with size less than 50cm x 60cm x70cm; Except for: 4.2.8 Cathode ray tube; 4.3.12 Flammable liquids; 4.3.13 radiation)

Shenzhen WST Testing Co., Ltd

87 Guangshen Road, Baocheng 11st Zone, Xin'an Street, Bao'an, Shenzhen, Guangdong

Tel: +86-755-2782 2785
Email: service@wstlab.cn

As detailed in the Laboratory Accreditation Certificate No. CNAS L9887 dated 17.04.2017 and the attached appendices for the scope of accreditation and excluding items issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 25.06.2021.

Classes of Electrical Products ... Standards Applicable

SLG-CPC Testaboratory Co., Ltd.

No. 11, Wu Song Road, Dongcheng District, Dongguan, Guangdong

Tel: +86-769-22607797
Fax: +86-769-22607907
Email: cpc@cpcteam.com

As detailed in the Laboratory Accreditation Certificate No. CNAS L0612 dated 07.01.2022 and the attached appendices for the scope of accreditation and excluding items issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 28.10.2022.

As detailed in the Laboratory Accreditation Certificate No. 6325.01 dated 04.10.2021 and the attached appendices for the scope of accreditation issued by the American Association for Laboratory Accreditation (A2LA) dated 15.06.2022.

As detailed in the category of products covered by the CB Scheme listed on the IECEE website in 2022 and the Certificate of testing laboratory dated 22 Nov 2022.

Classes of Electrical Products ... Standards Applicable

STC (Dongguan) Company Ltd.

Biaojian Keji Park, No. 68, Fumin South Road, Dalang, Dongguan, Guangdong, China

Tel: 86-769-81119888
Fax: 86-769-81116222

As detailed in the Laboratory Accreditation Certificate No. CNAS L3428 dated 1.4.2008 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 1.4.2008.

  • Household and similar electrical appliances :-
    • General requirements (Except for : transient voltage, software assessment, component tests, resistance rusting, toxic or similar materials, locking test for high power motor test > 4kW)
    • Vacuum cleaners and water-suction cleaning appliances (Except for : transient voltage, mechanical strength, software assessment, component tests, resistance rusting, toxic or similar materials, locking test for high power motor test > 4kW)
    • Grills, toasters and similar appliances (Except for : transient voltage, software assessment, component tests, resistance rusting, toxic or similar materials)
    • Kitchen machines (Except for : transient voltage, software assessment, component tests, resistance rusting, toxic or similar materials)
    • Heating liquids (Except for : transient voltage, software assessment, component tests, resistance rusting, toxic or similar materials)
    • Skin or hair care (Except for : transient voltage, software assessment, component tests, resistance rusting, toxic or similar materials)
    • Battery chargers (Except for : transient voltage, software assessment, component tests, resistance rusting, toxic or similar materials)
    • Room heaters (Except for : transient voltage, software assessment, component tests, resistance rusting, toxic or similar materials)
    • Oral hygiene appliances (Except for : transient voltage, software assessment, component tests, resistance rusting, toxic or similar materials)
    • Insect killers (Except for : transient voltage, software assessment, component tests, resistance rusting, toxic or similar materials)
    • Electric fans (Except for : software assessment, component tests, resistance rusting, toxic or similar materials)
  • Information technology equipment (Excluding :mechanical properties of cathode ray tube, radiation, general - ozone test)
  • Audio-video product (Excluding :radiation, heat resistance of insulating material, vibration test, component tests, mechanical tests)
  • Power transformer, power supply unit (Excluding : three-phase product, single-phase>500VA, rubber-parts are aged in an atmosphere of oxygen under pressure, component)
  • Isolating transformers for general use (Excluding : three-phase product, single-phase>500VA, rubber-parts are aged in an atmosphere of oxygen under pressure, component)
  • Safety isolating transformers for general use (Excluding : three-phase product, single-phase>500VA, rubber-parts are aged in an atmosphere of oxygen under pressure, component)
  • Transformers for toys (Excluding : three-phase product, single-phase>500VA, rubber-parts are aged in an atmosphere of oxygen under pressure, component)
  • Luminaries
    • General safety requirements (Excluding :lampholder construction and size)
    • Fixed general purpose luminaries (Excluding :lampholder construction and size)
    • Portable general purpose luminaries (Excluding :lampholder construction and size)
    • Lighting chains (Excluding : Edison screw lampholder E10, E14, E17 construction and size, light performance test)
    • Emergency lighting (Excluding : intensity distribution)
    • Lamp controlgear
    • Lamp controlgear - a.c. supplied electronic ballasts for fluorescent lamps (Excluding : emergency lighting)

Testing Center of Shanghai Electric Cable Research Institute
(China National Center for Quality Supervision and Testing of Electric Wire & Cable)

1000 Jungong Rd., Shanghai, PRC

Tel: 86-21-65494605
Fax: 86-21-65490171

As detailed in the Laboratory Accreditation Certificate No. CNAS L0207 dated 4.8.2009 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 4.8.2009.

  • Round wire concentric lay overhead electrical stranded conductors
  • Overhead electrical conductors - Formed wire, concentric lay, stranded conductors
  • Zinc-coated steel wires for stranded conductors
  • Aluminum-clad steel wires for electrical purposes
  • Recommendation for commercial annealed aluminum electrical conductor wire
  • Hard-drawn aluminum wire for overhead line conductors
  • Mineral insulated cables and their terminations with a rated voltage up to and including 750V
  • Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V
  • Heating cables with a rated voltage of 300/500V for comfort heating and prevention of ice formation
  • Rubber insulated cables of rated voltage up to and including 450/750V
  • Shipboard cables and wires
  • Single phase plugs and socket-outlets
  • Cord sets
  • Appliance couplers for household and similar general purposes
  • Adaptors
  • Low-frequency telecommunication cables and wires
  • Power cable with extruded insulation and their accessories (except for thermal short circuit、dynamic short circuit)
  • Paper-insulated power cables and their accessories (Except for dynamic frication coefficient, hazardous substance content)
  • Wire, cable and optical cable
  • Accessories for power cables with rated voltages from 6kV up to 35kV (Except for thermal short circuit、dynamic short circuit)
  • Overhead electrical conductors

Testing Laboratory of Shunde Entry-Exit Inspection and Quarantine Bureau

No. 2 Gangqian Road, RongGui, Shunde, Foshan, Guangdong, China

Tel: 86-757-26383528
Fax: 86-757-26623554

As detailed in the Accreditation Certificate No.L0540 and the attached appendices for the scope of accreditation issued by the China National Accreditation Board for Laboratories (CNAL) dated 26.12.2005

Household and similar electrical appliances:-

  • Microwave ovens;
  • Kitchen machines;
  • Toasters, grills, roasters;
  • Electric irons;
  • Vacuum cleaners and water suction cleaners appliances;
  • Stationary cooking ranges, hobs, ovens;
  • Deep fat fryers, frying pans;
  • Storage water heaters;
  • Room heaters;
  • Instantaneous water heaters;
  • Sauna heating appliances;
  • Water dispensing appliances and vending machines;
  • Appliances for skin or hair care;
  • Appliances for heating liquids
  • Electric fans;
  • Air-cleaning appliances;
  • Household use employing liquids or steam;
  • Massage appliances;
  • Electric warming plates and similar appliances;
  • Insect killers;
  • Spin extractors;
  • Washing machines;
  • Tumble dryers

Luminaires:-

  • Portable luminaries;
  • Fixed luminaries;
  • Recessed luminaries;
  • Lighting chains;
  • Ballasts for tabular fluorescent lamps;
  • a.c. supplied electronic ballasts for tubular fluorescent lamps.

Plugs and sockets-outlets for household and similar purposes:-

  • Socket-outlets for appliances;
  • Adaptors;

The Certification & Testing Center of Shenzhen LCS Certification Service Inc.

1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue, Bao’an District, Shenzhen, Guangdong, China

Tel: 86-0755-82591330
Fax: 86-0755-82591332

As detailed in the Laboratory Accreditation Certificate No. CNAS L4595 dated 04.06.2010 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 18.10.2011.

Classes of Electrical Products ... Standards Applicable

The Testing and Technology Center for Industrial Products of Shenzhen Entry-Exit Inspection and Quarantine Bureau

No. 149, 7th Industry Road,
Nanshan District,
Shenzhen, China

Tel: 86-0755-26673926
Fax: 86-0755-26673116

As detailed in the Laboratory Accreditation Certificate No. CNAS L2872 dated 5.3.2008 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 24.9.2008.

  • Household and similar electrical appliances :-
    • General requirements (Excluding oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Heating liquids (Excluding appliance with pressure, oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Kitchen machines (Excluding appliance used in ice box or refrigerator, oxygen bomb test, capacitance, automatic control, coupler)
    • Warming plates (Excluding oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Grills, toasters and similar electrical appliances (Excluding rotary grills, oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Automatic rice cookers (Excluding oxygen bomb test, capacitance; switch, automatic control, coupler)
    • Electric fans (Excluding partition and duct fan, oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Massage appliances (Excluding oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Cold and hot type drinking-water appliances (Excluding compressor, oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Skin or hair care (Excluding oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Shavers、hair clippers and similar appliances (Excluding oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Storage water heaters (Excluding press equipment, oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Electric irons (Excluding wireless iron insert test, electric irons with pressure, oxygen bomb test, capacitance; switch, automatic control, coupler)
    • Battery chargers (Excluding lead acid storage battery chargers, oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Humidifiers (Excluding oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Air-cleaning appliances (Excluding oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Surface-cleaning appliances for household use employing liquids or steam (Excluding cleaning appliances which are permanently fixed to a building, oxygen bomb test, capacitance; switch, automatic control, coupler)
    • Vacuum cleaners and water suction cleaning appliances (Excluding current-carrying hoses, oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Room heaters (Excluding oxygen bomb test, capacitance, switch, automatic control, coupler)
    • Deep fat fryers, frying pans (Excluding oxygen bomb test, capacitance, switch, automatic control, coupler)
  • Audio, video and similar electronic apparatus (Excluding resistance, capacitor, protect device)
  • Information technology equipment (Excluding high current arcing, hot wire ignition, hot flaming oil test)
  • Isolating transformers (Excluding insulated coat)
  • Plugs and socket-outlets
  • Socket-outlets for appliances
  • Adaptors
  • Luminaries
    • General safety requirements (Excluding test chain, test of power cord and internal connection cable, coupler, impulse test)
    • Portable general purpose luminaries (Excluding test of power cord and internal connection cable, coupler)
    • Recessed luminaries (Excluding test of power cord and internal connection cable, coupler)
    • Fixed general purpose luminaries (Excluding test of power cord and internal connection cable, coupler)
    • Luminaries with built-in transformers for filament lamps (Excluding test of power cord and internal connection cable, coupler)
    • Lighting chains (Excluding test of power cord and internal connection cable, coupler)

TMC Testing Services (Shenzhen) Co., Ltd.

1/F., Block A, Xinshidai Gongrong Industrial Park, No. 2, Shihuan Road, Shilong Community, Shiyan Street, Baoan District, Shenzhen, China

Tel: (86)135-10907826

As detailed in the Laboratory Accreditation Certificate No. CNAS L8364 dated 10.12.2020 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 10.12.2020.

Classes of Electrical Products ... Standards Applicable

Tongli Test Certification (Guangdong) Co. Ltd.

No. 2, Unit 801, Building 10, Tianfulai International Industrial Town, No. 3, Changfu West Road, Rongli Residential Committee, Ronggui, Shunde District, Foshan, Guangdong, China

Tel: 86 13929125862
Fax: 86 0757 2881 7122

As detailed in the Laboratory Accreditation Certificate No. CNAS L13386 dated 24.07.2020 and the attached appendices for the scope of accreditation and excluding items issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 12.01.2022.

Classes of Electrical Products ... Standards Applicable

TÜV Rheinland (Shanghai) Co., Ltd.

No.10 (1st Floor), No.153, No. 165, No. 177, No. 178, No. 179, No. 182, No. 189, No. 192, No. 198, Lane 777, West Guangzhong Road, Jing’an District, Shanghai

Tel: 86 21 61081188
Fax: 86 21 61081199

As detailed in the Laboratory Accreditation Certificate No. CNAS L3038 dated 30.10.2019 and the attached appendices for the scope of accreditation and excluding items issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 30.10.2019.

Classes of Electrical Products ... Standards Applicable

TUV SUD Certification & Testing (China) Co., Ltd. Guangzhou Branch

5/F. & East of 8/F., Communication Building, No. 163, Pingyun Road, West of Huangpu Avenue, Guangzhou, Guangdong, China

Tel: 8620 - 38320668
Fax: 8620 - 38320478

As detailed in the Laboratory Accreditation Certificate No. CNAS L3584 dated 14.08.2017 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 11.04.2018.

As detailed in Certificate of Acceptance to Participate in The IECEE CB-SCHEME No. TL240 dated 01.03.2017 and the attached appendices for the scope of IECEE CBTL.

  • Household and Similar Equipment
    • General requirements
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Vacuum cleaners
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards; clause 21.101, 21.102, 21.103, 21.104, 21.105)
    • Water suction cleaning
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards; clause 21.101, 21.102, 21.103, 21.104, 21.105)
    • Electric dry irons
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Electric steam irons
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Spin extractors
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Dishwashers
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Cooking ranges
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Washing machines
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Electric shavers
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Hair clippers
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Grills
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Induction hotplates
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Roasters
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Toasters
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Wet scrubbing machines
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Floor treatment machines
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Tumble dryers
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Warming plates
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Deep fat fryers
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Frying pans
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Electric kitchen machines
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Appliances for heating liquids
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Foot warmers and heating mats
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards;clause21.102.1, 21.102.1, 30.10
    • Electric toilets
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Fabric steamers
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Humidifiers
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Insect repellers
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Vaporizers
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Air fresheners
      (Excluding 22.32 Oxygen bomb test and ceramic material is tightly sintered test; 22.48 & IEC61770 prevent backsiphonage of non-potable water into the water mains test; annex F capacitors; annex J Coated printed circuit boards)
    • Power transformers and power supply units
      (Excluding 16 Vibrating test; 17 IP5X/IP6X test; 19 Oxygen bomb/mandrel testing for insulated wire test; 20 components exclude switch and European two pole plug)
  • Electronics, Entertainment
    • Amplifiers
      (Excluding 6.1 lonizing Radiation; 7.2 heat resistance of insulating material; 12.1.3 Vibration Test; 14.2, 14.3 capacitors and RC-units test; 14.6 protective Device (thermal cut-outs, fuse; 16.1 power supply cord)
    • Audio equipment
      (Excluding 6.1 lonizing radiation; 7.2 heat resistance of insulating material; 12.1.3 Vibration Test; 14.2, 14.3 capacitors and RC-units test; 14.6 protective Device (thermal cut-outs, fuse; 16.1 power supply cord)
    • Karaoke equipment
      (Excluding 6.1 lonizing radiation; 7.2 heat resistance of insulating material; 12.1.3 Vibration Test; 14.2, 14.3 capacitors and RC-units test; 14.6 protective Device (thermal cut-outs, fuse; 16.1 power supply cord)
    • Television
      (Excluding 6.1 lonizing radiation; 7.2 heat resistance of insulating material; 12.1.3 Vibration Test; 14.2, 14.3 capacitors and RC-units test; 14.6 protective Device (thermal cut-outs, fuse; 16.1 power supply cord)
    • Video equipment
      (Excluding 6.1 lonizing radiation; 7.2 heat resistance of insulating material; 12.1.3 Vibration Test; 14.2, 14.3 capacitors and RC-units test; 14.6 protective Device (thermal cut-outs, fuse; 16.1 power supply cord)
  • Information technology equipment
    • Copying machine
      (Excluding Cl. 1.5 capacitor, thermal controls, surge suppressors; Cl. 2.10 wire in wound component, abrasion resistance test Cl. 4.2.8: Cathode ray tubes; Cl. 4.3.12: flammable liquids; Cl. 4.3.13.2: ionizing radiation; Cl. 4.3.13.3-4.3.13.4: UV radiation; Annex H Ionizing radiation; Annex K Thermal controls; Annex M Criteria for telephone ringing signals; Annex N Impulse test generators; Annex S Procedure for impulse testing; Annex U Insulated winding wires for use without interleaved insulation)
    • Data processing equipment
      (Excluding Cl. 1.5 capacitor, thermal controls, surge suppressors; Cl. 2.10 wire in wound component, abrasion resistance test Cl. 4.2.8: Cathode ray tubes; Cl. 4.3.12: flammable liquids; Cl. 4.3.13.2: ionizing radiation; Cl. 4.3.13.3-4.3.13.4: UV radiation; Annex H Ionizing radiation; Annex K Thermal controls; Annex M Criteria for telephone ringing signals; Annex N Impulse test generators; Annex S Procedure for impulse testing; Annex U Insulated winding wires for use without interleaved insulation)
    • Facsimile machine
      (Excluding Cl. 1.5 capacitor, thermal controls, surge suppressors; Cl. 2.10 wire in wound component, abrasion resistance test Cl. 4.2.8: Cathode ray tubes; Cl. 4.3.12: flammable liquids; Cl. 4.3.13.2: ionizing radiation; Cl. 4.3.13.3-4.3.13.4: UV radiation; Annex H Ionizing radiation; Annex K Thermal controls; Annex M Criteria for telephone ringing signals; Annex N Impulse test generators; Annex S Procedure for impulse testing; Annex U Insulated winding wires for use without interleaved insulation)
    • Modem
      (Excluding Cl. 1.5 capacitor, thermal controls, surge suppressors; Cl. 2.10 wire in wound component, abrasion resistance test Cl. 4.2.8: Cathode ray tubes; Cl. 4.3.12: flammable liquids; Cl. 4.3.13.2: ionizing radiation; Cl. 4.3.13.3-4.3.13.4: UV radiation; Annex H Ionizing radiation; Annex K Thermal controls; Annex M Criteria for telephone ringing signals; Annex N Impulse test generators; Annex S Procedure for impulse testing; Annex U Insulated winding wires for use without interleaved insulation)
    • Telephone answering machines
      (Excluding Cl. 1.5 capacitor, thermal controls, surge suppressors; Cl. 2.10 wire in wound component, abrasion resistance test Cl. 4.2.8: Cathode ray tubes; Cl. 4.3.12: flammable liquids; Cl. 4.3.13.2: ionizing radiation; Cl. 4.3.13.3-4.3.13.4: UV radiation; Annex H Ionizing radiation; Annex K Thermal controls; Annex M Criteria for telephone ringing signals; Annex N Impulse test generators; Annex S Procedure for impulse testing; Annex U Insulated winding wires for use without interleaved insulation)
    • Typewriter
      (Excluding Cl. 1.5 capacitor, thermal controls, surge suppressors; Cl. 2.10 wire in wound component, abrasion resistance test Cl. 4.2.8: Cathode ray tubes; Cl. 4.3.12: flammable liquids; Cl. 4.3.13.2: ionizing radiation; Cl. 4.3.13.3-4.3.13.4: UV radiation; Annex H Ionizing radiation; Annex K Thermal controls; Annex M Criteria for telephone ringing signals; Annex N Impulse test generators; Annex S Procedure for impulse testing; Annex U Insulated winding wires for use without interleaved insulation)
    • Visual display units for computer
      (Excluding Cl. 1.5 capacitor, thermal controls, surge suppressors; Cl. 2.10 wire in wound component, abrasion resistance test Cl. 4.2.8: Cathode ray tubes; Cl. 4.3.12: flammable liquids; Cl. 4.3.13.2: ionizing radiation; Cl. 4.3.13.3-4.3.13.4: UV radiation; Annex H Ionizing radiation; Annex K Thermal controls; Annex M Criteria for telephone ringing signals; Annex N Impulse test generators; Annex S Procedure for impulse testing; Annex U Insulated winding wires for use without interleaved insulation)
  • Plugs
    • 3-pin 13A plug

TUV SUD Certification and Testing (China) Co., Ltd. Shenzhen Branch

6/F, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen, Guangdong, China

Tel: 86-755-33323281
Fax: 86-755-88285299

As detailed in the Laboratory Accreditation Certificate No. CNAS L4287 dated 21.1.2014 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 29.11.2012.

  • Household appliances:-

    • General requirements (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Vacuum cleaners and water suction cleaning appliances (Excluding mechanical strength testing for current –carrying hoses, EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Electric Irons (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Cooking ranges, cooking tables, ovens and similar appliances (Excluding the pyrolytic self-cleaning oven, EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Electric shaves, hair clippers and similar appliances (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Toasters, grills, roasters and similar appliances (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Warming plates and similar appliances (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Deep fat fryers, frying pans and similar appliances (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Kitchen machines (Excluding PVC supply cord resistant to low temperatures, chemical stress test, EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Appliances for heating liquids (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Blankets, pads clothing and similar flexible heating appliances (Excluding detachable washable heating blanket and heating pad, EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Appliances for skin or hair care (Excluding hairdryer with hood attachment, EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Microwave ovens (Excluding construction, EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Sewing machines (Excluding oxygen bomb test, ceramic material test, EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Battery chargers (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Room heaters (Excluding 2.5Nm torque test to panel in each direction, EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Massage appliances (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Clothes dryers and towel rails (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Portable heating tools and similar appliances (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Surface-cleaning appliances employing liquids (Excluding product with current carrying hose, EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Air-cleaning appliances (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Electrical heating appliances for breeding and rearing animals (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Outdoor barbecues (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Electric Fans (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Foot warmers and heating mats (Excluding heating pad, EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Humidifiers (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
    • Vaporizers (Excluding EMC test, oxygen bomb test, ceramic material test, components, test according to ISO2178 and ISO1463, capacitor, test for coating of PCB, software evaluation testing)
  • Audio, video and similar electronic apparatus (Excluding radiation test, endurance test for wound components, vibration test, resistors, capacitors and RC-units test, protective devices, endurance test to main switch, AC power supply flexible cord, live flexible cord, mechanical strength of picture tubes and protection against the effects of implosion, test methods, resistance to fire, flammability, insulated winding wires for use without interleaved insulation)

  • Information technology equipment (Excluding thermal controls, capacitors, TIW, test for AC Power supply cord, test for cathode ray tube, flammable liquids test, radiation test, distillate fuel oil test, test for adhesives for constructional purposes, test for classed material, flammability test, ionizing radiation, insulated winding wires for use without interleaved insulation)

  • Luminaires

    • General safety requirements
    • Fixed general purpose luminaries
    • Recessed luminaries
    • Portable general purpose luminaries
    • Luminaries with built-in transformers for filament lamps
    • Portable luminaries for garden use
    • Portable luminaries for children (Excluding tests according to ISO8124, burning behavior of ISO 6941)
    • Lighting chains (Excluding mechanical strength of flexible sealed lighting chains)
    • Self-ballasted LED lamps for general lighting services by voltage > 50 V
    • LED modules for general lighting
  • Laser Products (Including laser products with wavelength: 250 ~ 800nm, power: 11.1pw ~ 200mW only)

  • Power transformers, power supply units and similar products

    • General requirements and tests (Excluding oxygen bomb test, test for appliance couplers, fuse testing, test for thermal cut-outs, test for thermal-link, insulated winding wires for use as multiple layer insulation)
    • Isolating transformers (Excluding oxygen bomb test, test for appliance couplers, fuse testing, test for thermal cut-outs, test for thermal-link, insulated winding wires for use as multiple layer insulation)
    • Safety isolating transformers (Excluding oxygen bomb test, test for appliance couplers, fuse testing, test for thermal cut-outs, test for thermal-link, insulated winding wires for use as multiple layer insulation)
    • Transformers for toys (Excluding oxygen bomb test, test for appliance couplers, fuse testing, test for thermal cut-outs, test for thermal-link, insulated winding wires for use as multiple layer insulation)
    • Transformers for switch mode power supplies (Excluding oxygen bomb test, test for appliance couplers, fuse testing, test for thermal cut-outs, test for thermal-link, insulated winding wires for use as multiple layer insulation)
  • Electric Toys (Excluding component test, radiation, toxicity and similar hazards, automatic controls and switches, toys incorporating lasers and light-emitting diodes)

  • Adaptors

    • 13A Adaptors (Including partial tests on plug portion of direct plug-in equipment and direct plug-in adaptor)

Ulab Testing Co., Ltd.

3/F., Building 6A, Innovation Base of Dongguan Polytechnic, No.3, Daxue Road, Songshanhu Hi-Tech Zone, Dongguan, Duangdong, China

Tel: 0769-22210225
Fax: 0769-22210296

As detailed in the Laboratory Accreditation Certificate No. CNAS L10843 dated 2018.03.21 and the attached appendices for the scope of accreditation and excluding items issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 2018.03.21.

Classes of Electrical ProductsStandards Applicable
Information technology equipment
  Data processing equipment

IEC 60950*

Visual Display Units for computer

IEC 60950*

Power supply unit for information technology equipment

IEC 60950*

Audio, video and similar electronic apparatus
 

Television

IEC 60065*

Video equipment

IEC 60065*
Remark:
* Excluding items can be referred to Laboratory Accreditation Certificate (No. CNAS L10843) dated 2018.03.21 and the attached appendices for the scope of accreditation and excluding items issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 2018.03.21.

Vkan Certification & Testing Co., Ltd.

No.3, Tiantai 1st Road, Kaitai Avenue, Science City, Luogang District, Guangzhou, Guangdong, China

Tel: 86 20 3229 3683
Fax :86 20 3229 3889

As detailed in the Laboratory Accreditation Certificate No. CNAS L0095 dated 13.8.2018 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 21.8.2018.

  • Stationary circulation pumps;
  • Appliances for use with aquariums and garden;
  • Walk-behind and hand-held lawn trimmers and lawn edge trimmers;
  • Drives for vertically moving garage doors for residential use;
  • Rolling shutters, awnings, blinds and similar equipments;
  • Luminaries with limited surface temperatures/light;
  • Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - non-sheathed cable for fixed wiring;
  • Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - sheathed cable for fixed wiring;
  • Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Flexible cable (cords);
  • Rubber insulated cables of rated voltages up to and including 450/750V- heat resistant silicone rubber insulated cable;
  • Cables of rated voltages up to and including 450/750V and having cross-linked insulation - Part 4: Cords and flexible cables;
  • Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - General requirements;
  • Rubber insulated cables of rated voltages up to and including 450/750V;
  • Electrical heat pumps, air conditioners and dehumidifiers (Household appliances);
  • Particular requirements for refrigerating appliances, ice-cream appliances and ice-makers (Household appliances);
  • Household appliances (General requirement);
  • Appliances for skin or hair care (Household appliances);
  • Instantaneous water heaters (Household appliances);
  • Storage water heaters (Household appliances);
  • Appliances for heating liquids (Household appliances);
  • Micro-wave ovens (Household appliances);
  • Room heaters (Household appliances);
  • Appliances and vending machines (Household appliances);
  • Sauna heating appliances (Household appliances);
  • Air cleaning appliances (Household appliances);
  • Requirements for humidifiers (Household appliances);
  • Massage appliances (Household appliances);
  • Tumble dryers (Household appliances);
  • Washing machines (Household appliances);
  • Dishwashers (Household appliances);
  • Spin extractors (Household appliances);
  • Kitchen machines (Household appliances);
  • Food waste disposers (Household appliances);
  • Floor treatment machines and wet scrubbing machines (Household appliances);
  • Sewing machines (Household appliances);
  • Amusement machines and personal service machines (Household appliances);
  • Fans (Household appliances);
  • Vacuum cleaners and water suction cleaning appliances (Household appliances);
  • Range hoods (Household appliances);
  • Oral hygiene appliances (Household appliances);
  • Surface cleaning appliances (Household appliances);
  • Battery chargers (Household appliances);
  • Electric irons;
  • Deep fat fryers, frying pans and similar appliances;
  • Automatic rice cookers;
  • Blankets, pads and similar flexible heating appliances;
  • Electric shavers, hair clippers and similar appliances;
  • Roasters, grills, roasts and similar appliances;
  • Cooking ranges, cooking tables, ovens and similar appliances for household use;
  • Portable heating tools and similar appliances;
  • Warming plates and similar appliances;
  • Clothes dryers and towel rails;
  • Outdoor barbecues;
  • Particular requirements for toilets;
  • Fabric steamers;
  • Whirlpool baths;
  • Hand held motor-operated electric tools/electric tools;
  • D.C. or a.c. supplied electronic step down convertors for filament lamps/light;
  • Ballasts for florescent lamps/light;
  • Discharge lamps (excluding fluorescent lamps/light,
  • Filament lamps;
  • Luminaries- general requirements;
  • Electrical supply track system/light;
  • Edison screw lamp holders;
  • Lamp holders for tubular fluorescent lamps and starters holders;
  • Luminaries for emergency lighting;
  • Portable luminaries for garden use;
  • Portable child appealing luminaries;
  • Luminaries for road and street lighting;
  • Luminaries with built-in transformers for filament lamps;
  • Flood light;
  • Luminaries for swimming pools and similar applications;
  • Lighting chains;
  • Fixed luminaries;
  • Portable luminaries;
  • Recessed luminaries;
  • Air handling luminaries;
  • Photo and film luminaries (non-professional);
  • Bayonet lampholders;
  • Single capped fluorescent lamps;
  • Self ballast lamps for general lighting services;
  • A.C. supplied electronic ballasts for fluorescent lamps;
  • Power transformers;
  • Appliance couplers for household and similar general purposes;
  • Switches for household and similar fixed electrical installations;
  • Electronic switches;
  • Remote control switches;
  • Plugs and socket outlets for household and similar purposes;
  • Connecting devices for low voltage circuits/accessory;
  • Conduit for electrical installation;
  • Miniature cartridge fuse links;
  • Low-voltage fuses;
  • Circuit breakers for overcurrent protection for household and similar installation;
  • Residual current operated circuit breakers without integral overcurrent protection for household and similar uses;
  • Residual current operated circuit breakers with integral overcurrent protection for household and similar uses;
  • Flat quick connect terminations for electrical copper conductors;
  • Plugs, sockets outlets, adaptors and connection units;
  • Information technology equipment;
  • Audio, video and similar electronic apparatus;
  • Power transformers, power supply units and similar;
  • Isolating transformers;
  • Safety isolating transformers;
  • Bell and chime transformers;
  • Transformers for switch mode power supplies;
  • Safety of power transformers;
  • Cord switches;
  • Thermal links;
  • Automatic electrical controls for household and similar use;
  • Thermal motor protectors;
  • Thermal protectors for ballasts for tubular fluorescent lamps;
  • Timers and time switches;
  • Electrically operated water valves;
  • Temperature sensing controls.

Waltek Services (Shenzhen) Co., Ltd.
(Waltek EMC Lab)

12B, West Tower, AiDi Building, No.5003 BinHe Rd, FuTian District, Shenzhen, China

Tel: 0755-27553488
Fax: 0755-27553868

As detailed in the Laboratory Accreditation Certificate No. CNAS L3110 dated 28.6.2007 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 20.7.2009.

Classes of Electrical Products ... Standards Applicable

Waltek Testing Group (Foshan) Co., Ltd.

No. 13-19, 2/F, 2nd Building, Sunlink International Machinery City, Chencun, Shunde District, Foshan, Guangdong, China

Tel: 0757-2381 1398
Fax: 0757-2381 1381

As detailed in the Laboratory Accreditation Certificate No. CNAS L6478 dated 26.9.2016 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 26.9.2016.

  • Household and similar electrical appliances
    • Household and similar electrical appliances (Except for: 22.3 socket-outlet pins strain test, 22.32 oxygen bomb test, 22.48 backsiphonage test, 22.46 software evaluation, Chapter 24 components (Capacitances, Lamp holders, Isolating transformers, Couplers, Automatic controls)
    • Electric dry irons, Electric steam irons, irons
    • Vacuum cleaners and water-suction cleaning appliance
    • Massage appliances
    • Instantaneous water heaters (Except for: 22.102 pressure test)
    • Storage water heaters (Except for: 22.102 pressure test, 22.104 vacuum impact test)
    • Induction cookers, grills, toasters and similar portable cooking appliances
    • Electric hair dryers, appliances for skin or hair care
    • Battery chargers (Except for: Shrinkage supply cord Life test)
    • Appliances for heating liquids
    • Tumble dryers
    • Stationary cooking ranges, hobs, ovens and similar appliances
    • Room heaters
    • Washing machines
    • Dishwashers
    • Spin extractors
    • Electric fans
    • Range hoods
    • Electric kitchen machines
    • Electric pumps for liquids
    • Air-cleaning appliances
    • Warming plates and similar appliances
    • Deep fat fryers, frying pans and similar appliances
    • Clothes dryers and towel rails
    • Surface-cleaning appliances for household use employing liquids or steam
    • Insect killers
    • Electric shavers, hair clippers and similar appliances
    • Refrigerators, food freezers, refrigerating appliances, ice-cream appliances and ice-makers (Except for: camping appliances, flammable refrigerators, vibration test)
    • Motor compressors (Except for: 13.3 electric strength in normal use, 19 abnormal temperature)
    • Electrical heat pumps, air-conditioners and dehumidifiers (Only for: portable air-conditioners, dehumidifiers and sanitary hot water heat pump)
    • Portable heating tools and similar appliances
    • Projectors and similar appliances
    • Thermal storage room heaters
    • Humidifiers
    • Food waste disposers
    • Electric toilets (Except for: 21.101, 22.103)
    • Floor treatment machines and wet scrubbing machines
    • Oral hygiene appliances
    • Electrical appliances for use with aquariums and garden ponds
    • Drives for vertically moving garage doors for residential use
    • Clocks
    • Whirlpool baths and whirlpool spas
    • Portable immersion heaters
    • Electric ironers
    • Fabric steamers
    • Multi-functional shower cabinets (Except for: volume over 2.5*2.5*3 meters)
    • Blankets, pads, clothing and similar flexible heating appliances
    • Electrical heating appliances for breeding and rearing animals
    • Foot warmers and heating mats
    • Sewing machines
    • Sauna heating appliances and infrared cabins
    • Stationary circulation pumps for heating and service water installations
    • Water-bed heaters
    • Fixed immersion heaters
    • Outdoor barbecues
    • Gas, oil and solid-fuel burning appliances having electrical connections(Except for:8.101 igniters test)
    • Drives for gates, doors and windows
    • Amusement machines and personal service machines
    • Pedestrian controlled mains-operated lawnmowers(Except for:20.102 Braking requirements, 20.103 Requirements for rotary mowers, 21.101 Requirements for rotary mowers)
    • Walk-behind and hand-held lawn trimmers and lawn edge trimmers(Except for:21.101.3 drop test, 21.102 Strength of the cutting head, 22.103 moving energy)
    • Hand-held mains-operated garden blowers, vacuums and blower vacuums
    • Electric toys(Except for: radiation, toxic gas, laser, switch, automatic control device)
    • Mincing machines
  • Information technology equipment
    • Information technology equipment (Photocopiers, Data processing equipment, Fax machines, Mediation, Telephone recorder, Typewriter, Computer display) (Except for: three-phase equipment and part of Parameters: Annex K Thermal controls, 1.5.6 Capacitors bridging insulation, 1.5.7 Resistors bridging insulation, 1.5.9 Surge suppressors;
      Except for:2.3.1 TNV circuits;
      Except for:2.10.3.6 Measurement of transient voltages, 2.10.8.4 Abrasion resistance test;
      Except for:4.2.8 mechanical strength of CRT, 4.2.9 High pressure lamps;
      Except for:4.3.12 Flammable liquids, 4.3.13 Radiation;
      Except for:6.2.2.1 Impulse test)
  • Electronic, Entertaining Appliance
    • Audio, video and similar electronic apparatus(Except for: three-phase equipment;
      Except for:7.2 Heat resistance of insulating material;
      Except for:8.17 Endurance test of insulated winding wire;
      Except for:10.1 Surge test;
      Except for:12.1.2 Vibration test,12.5 Antenna coaxial sockets mounted on the apparatus;
      Except for:13.3.4 Measurement of transient voltages;
      Except for:16.3 flexing test for screened cords;
      Except for:19.5.1 Fragmentati on test)
    • Audio/video, information And communication technology equipment (Except for: three-phase equipment, 5.4.2.3.2.5 Measurement of transient voltages,5.4.1.10.2 the Vicat test;
      Except for:7.3 the concentration of ozone;
      Except for:8.5.5 High pressure lamps, 8.6.4 Glass slide test)
  • Hand-held motor-operated electric tools
    • Hand-held motor-operated electric tools (Except for: Three phase appliance, Rubber aging test(21.13), Cendactor damage test(25.1))
    • Drills and impact drills
    • Screwdrivers and impact wrenches
  • Luminaires
    • Luminaires (Except for : 4.14.1 Clip-mounted luminaires tested on metal rod, 4.20 Vibration test)
    • Luminaires for emergency
    • Portable luminaires for garden use
    • Portable child- appealing luminaries
    • Luminaires for road and street lighting
    • Luminaries with built-in transformers for filament lamps
    • Floodlights
    • Luminaries for swimming pools and similar applications
    • Lighting chains
    • Luminaires, fixed, general purpose
    • Portable general purpose luminaires
    • Recessed luminaires
    • Handlamps
    • Luminaires for aquarium
    • Nightlights
    • Ground recessed luminaires
    • Electrical supply track systems for luminaires
    • Self ballasted lamp (Chapter 6 lamp gauges can tested with E27 E14,E17,GU10,G9 lamp gauges only)
    • Lamp controlgear
    • D.C. or A.C. supplied electronic step-down convertors for filament lamps
    • A.C. supplied electronic ballasts for tubular fluorescent lamps
    • Ballasts for tabular fluorescent lamps
    • Miscellaneous electronic circuits used with luminaires
    • D.C. or A.C. supplied electronic controlgear for LED modules
    • D.C. supplied electronic ballasts for emergency lighting
    • Ballasts for discharge lamps (excluding fluorescent lamps)
    • Air-handling luminaires (safety requirements)
    • LED modules for general lighting
    • Double-capped fluorescent lamps
    • Single-capped fluorescent lamps
    • Photobiological safety of lamps and lamp systems
    • Self-ballasted LED-lamps for general lighting services by voltage > 50 V(Chapter 6 lamp gauges can tested with E27,E14,E17,GU10,G9 lamp gauges only)
    • D.C. or A.C. supplied electronic ballasts for discharge lamps (excluding fluorescent lamps)
    • Double-capped LED lamps designed to retrofit linear fluorescent lamps - Safety specifications(Chapter 6 lamp gauges can tested with G13 lamp gauges only)
  • Plugs
    • IEC plug (special adaptor to be added to convert the plug for compliance with BS 5733, BS 546 or BS 1363 Part 1) (Except for: Chapter 12 stud terminals, Chapter 16 products other than IP20 degree)
  • Switches for Appliances and Automatic Controls for Electrical Household Appliances
    • Switches for appliances (Except for: Chapter 25.1.5 Radiated electromagnetic field test)
  • Installation Accessories and Connection Devices
    • Switches (Except for: Chapter 12 stud terminals, Chapter 15 products other than IP20 degree)

Waltek Testing Group Co., Ltd.

No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China

Tel: 0769-22676998-197
Fax: 0769-22676828
Email: suker.zhang@waltek.com.cn

As detailed in the Laboratory Accreditation Certificate No. CNAS L3110 dated 19.10.2022 and the attached appendices for the scope of accreditation and excluding items issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 19.10.2022.

Classes of Electrical Products ... Standards Applicable

World Standardization Certification & Testing (Shenzhen) Co., Ltd.

Building A, Baoshi Road, Baoshi Science & Technology Park, Baoan District, Shenzhen, Guangdong, China

Tel: 86-755-26996192
Fax: 86-755-26996253

As detailed in the Laboratory Accreditation Certificate No. CNAS L3732 dated 28.10.2008 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 28.10.2008.

  • Household and similar electrical appliances :-

    • General requirements (Excluding IP degree, supply cord flexing test, transient overvoltage, software evaluation, ceramic material or synthetic rubber insulation test, metal frame test, pressure test, conductors flexing, resistance to rusting, radiation, toxicity and similar hazards)
    • Electric fans (Excluding IP degree, supply cord flexing test, transient overvoltage, software evaluation, ceramic material or synthetic rubber insulation test, metal frame test, pressure test, conductors flexing, resistance to rusting, radiation, toxicity and similar hazards)
    • Room heaters (Excluding IP degree, supply cord flexing test, transient overvoltage, software evaluation, ceramic material or synthetic rubber insulation test, metal frame test, pressure test, conductors flexing, resistance to rusting, radiation, toxicity and similar hazards)
    • Skin or hair care appliances (Excluding IP degree, supply cord flexing test, transient overvoltage, software evaluation, ceramic material or synthetic rubber insulation test, metal frame test, pressure test, conductors flexing, resistance to rusting, radiation, toxicity and similar hazards)
    • Grills, toasters and similar portable cooking appliances (Excluding IP degree, supply cord flexing test, transient overvoltage, software evaluation, ceramic material or synthetic rubber insulation test, metal frame test, pressure test, conductors flexing, resistance to rusting, radiation, toxicity and similar hazards)
    • Heating liquid appliances (Excluding IP degree, supply cord flexing test, transient overvoltage, software evaluation, ceramic material or synthetic rubber insulation test, metal frame test, pressure test, conductors flexing, resistance to rusting, radiation, toxicity and similar hazards)
    • Humidifiers (Excluding IP degree, supply cord flexing test, transient overvoltage, software evaluation, ceramic material or synthetic rubber insulation test, metal frame test, pressure test, conductors flexing, resistance to rusting, radiation, toxicity and similar hazards)
  • Audio, video and similar electronic apparatus (Excluding ionizing radiation, laser radiation, softening test for insulation material, surge test, vibration test, mechanical strength of picture tubes, components test excluded transformer)

  • Information technology equipment (Excluding ionizing radiation, laser radiation, mechanical strength of picture tubes, components test excluded transformer, connection to telecommunication networks, surge test)

  • Safety Isolating transformers (Excluding IP degree, insulation tracking test and insulation material mechanical strength, single phase transformers greater than 5kVA and three phase transformers)

  • Transformers for switch mode power supplies (Excluding IP degree, insulation tracking test and insulation material mechanical strength, single phase transformers greater than 5kVA and three phase transformers)

  • Electrical equipment for measurement, control, and laboratory use (Excluding IP degree, protection against radiation including laser sources, sonic and ultrasonic pressure, protection against liberated gases, explosion and implosion)

  • Luminaries :-

    • General safety requirements (Excluding Ultraviolet radiation, lamp protection test, resistance to dust and moisture, endurance test and thermal heat, short circuit, resistance to rusting, vibration test, resistance to tracking)
    • Fixed general purpose luminaries (Excluding Ultraviolet radiation, lamp protection test, resistance to dust and moisture, endurance test and thermal heat, short circuit, resistance to rusting, vibration test, resistance to tracking)
    • Portable general purpose luminaries (Excluding Ultraviolet radiation, lamp protection test, resistance to dust and moisture, endurance test and thermal heat, short circuit, resistance to rusting, vibration test, resistance to tracking)
    • Lighting chains (Excluding Resistance to dust and moisture, resistance to tracking)
    • Electronic ballasts (Excluding Heating test, tracking test, resistance to corrosion)
    • Electronic step-down converters (Excluding Heating test, tracking test, resistance to corrosion)

Zhejiang Academy of Science & Technology for Inspection & Quarantine

No. 398, Jianshe Sanlu, Xiaoshan District, Hangzhou, ZhejiangTi

Tel: 86-571-83527087
Fax: 86-571-83527100

As detailed in the Laboratory Accreditation Certificate No. CNAS L0354 dated 15.10.2019 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 08.08.2019.

Classes of Electrical Products ... Standards Applicable

Zhongshan DQC Testing Technology Co., Ltd.

1/F., No.151, Dongfu 3rd Road, Dongfeng, Zhongshan, Guangdong, China

Tel: 86-760-22788856
Fax: 86-760-23309181

As detailed in the Laboratory Accreditation Certificate No. CNAS L10704 dated 30.1.2018 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 30.1.2018.

  • Household and Similar Equipment
    • Household and similar electrical appliances
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Toasters, grills and roasters
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Warming plates
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Deep fat fryers, frying pans
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Electric kitchen machines
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Appliance for heating liquids
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Appliances for skin or hair care
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Room heaters
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Range hoods
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Air-cleaning appliances
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Electric fans
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Humidifiers
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Cooking ranges and ovens
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Storage water heaters
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

    • Clothes dryers and towel rails
      (Except for: 19.9(Motor overload test), 19.11.4(EMC), 22.3(impose undue strain on socket-outlets test), 22.16(Automatic coiling test), 22.32(Magenta and oxygen bomb), 22.46(software evaluation), 22.48(The siphon proof test), Annex C Ageing test on motors, Annex D Thermal motor protectors, Annex F Capacitors, Annex G Safety isolating transformers, Annex J Coated printed circuit boards, Annex Q Sequence of tests for the evaluation of electronic circuits, Annex R Software evaluation)

  • Lighting
    • Luminaires
      (Except for:4.11.6(Electro-mechanical contact system), 4.14.6(Strain on socket-outlets), 4.18.2(Copper corrosion), 4.20(Vibration requirements), 4.24 (Photobiological hazards), 4.26(Short circuit protection), 4.28(Fixing of thermal sensing controls), 9.2.9(IPX8), Luminaires for metal halide lamps and some high pressure sodium vapour lamps with rectifying effects)

    • Luminaries, fixed, general purpose
      (Except for:4.11.6(Electro-mechanical contact system), 4.14.6(Strain on socket-outlets), 4.18.2(Copper corrosion), 4.20(Vibration requirements), 4.24 (Photobiological hazards), 4.26(Short circuit protection), 4.28(Fixing of thermal sensing controls), 9.2.9(IPX8), Luminaires for metal halide lamps and some high pressure sodium vapour lamps with rectifying effects)

    • Recessed luminaires
      (Except for:4.11.6(Electro-mechanical contact system), 4.14.6(Strain on socket-outlets), 4.18.2(Copper corrosion), 4.20(Vibration requirements), 4.24 (Photobiological hazards), 4.26(Short circuit protection), 4.28(Fixing of thermal sensing controls), 9.2.9(IPX8), Luminaires for metal halide lamps and some high pressure sodium vapour lamps with rectifying effects)

    • Portable general purpose luminaires
      (Except for:4.11.6(Electro-mechanical contact system), 4.14.6(Strain on socket-outlets), 4.18.2(Copper corrosion), 4.20(Vibration requirements), 4.24 (Photobiological hazards), 4.26(Short circuit protection), 4.28(Fixing of thermal sensing controls), 9.2.9(IPX8), Luminaires for metal halide lamps and some high pressure sodium vapour lamps with rectifying effects)

    • Floodlights
      (Except for:4.11.6(Electro-mechanical contact system), 4.14.6(Strain on socket-outlets), 4.18.2(Copper corrosion), 4.20(Vibration requirements), 4.24 (Photobiological hazards), 4.26(Short circuit protection), 4.28(Fixing of thermal sensing controls), 9.2.9(IPX8), Luminaires for metal halide lamps and some high pressure sodium vapour lamps with rectifying effects)

    • Self-ballasted LED Lamps for general lighting services by Voltage >50V - Safety Specifications
      (Interchangeability Accredited only for: E14, E27, GU10 caps. Mechanical strength accredited only for E14, E27, B22d caps)

    • Lamp controlgear
      (Except for: Annex G Explanation of the derivation of the values of pulse voltages)

    • Miscellaneous electronic circuits used with luminaires
      (Except for: Annex G Explanation of the derivation of the values of pulse voltages)

    • D.C. or A.C. supplied electronic controlgear for LED modules
      (Except for: Annex G Explanation of the derivation of the values of pulse voltages for IEC/EN standard, I.6.3 test and Annex G for GB standard

    • LED modules for general lighting - safety specifications

Zhongshan Entry-Exit Inspection and Quarantine Bureau Inspection and Quarantine Technique Center

No. 2 Zhongshan Six Road, Zhongshan, Guangdong, China

Tel: 86-760-8887899
Fax: 86-760-8887890

As detailed in the Laboratory Accreditation Certificate No. CNAS L1819 dated 06.11.2007 and the attached appendices for the scope of accreditation issued by the China National Accreditation Service for Conformity Assessment (CNAS) dated 06.11.2007.

  • Household and similar electrical appliances
    • General requirement (clauses 10,15,16,25 and 27)
    • Electric irons (clauses 10,15,16,25 and 27)
    • Electric rice cooker (clauses 10,15,16,25 and 27)
    • Vacuum cleaners (clauses 10,15,16,25 and 27)
    • Shavers, hair clippers (clauses 10,15,16,25 and 27)
    • Massage appliances (clauses 10,15,16,25 and 27)
    • Appliances for skin or hair care (clauses 10,15,16,25 and 27)
    • Appliances for heating liquids (clauses 10,15,16,25 and 27)
    • Blenders (clauses 10,15,16,25 and 27)
    • Room heaters (clauses 10,15,16,25 and 27)
    • Washing machine (clauses 10,15,16,25 and 27)
    • Fans (clauses 10,15,16,25 and 27)
    • Air cleaning appliances (clauses 10,15,16,25 and 27)
  • Luminaries
    • General requirement
    • Fixed general purpose luminaries
    • Portable general purpose luminaries
    • Recessed luminaries
    • Luminaries with built-in transformers for filament lamps
    • Self-ballasted lamps for general lighting services
    • Transformers
    • Ballasts for fluorescent lamps